English
LD-G-2
Page 10
Kick function
: It is possible to set the function outputs so that they
get the full voltage first for up to seven seconds and then are dimmed.
Example of use: For some types of electric couplings you need the full
voltage for decoupling and the voltage then reduced to protect the
couplings.
Check back of the address
In the programming mode you can query the address. The address is
transmitted coded by the flashing of the lighting of the locomotive.
Online-programming
The address, the driving characteristics and all functions can be
programmed online. This means:
§
In order to start the programming mode and to set the desired
(new) address, it is not necessary to enter the present address.
§
While programming the driving characteristics (starting and
maximum velocity, acceleration and brake delay) the locomotive is
running. By operating the speed knob the driving characteristics are
altered. As soon as these are set as desired, they can be saved
directly (online).
§
In the programming mode the function to be set is active. This
makes it easier to assign the outputs to the function keys. The
dimming and the kick function can be altered via the speed knob.
As soon as they are set as desired, they can be saved directly
(online).
Restrictions in Motorola I format
In Motorola I Format the following settings can be made:
§
address
§
starting and maximum velocity
§
assignment of the funciton outputs to „function“
In Motorola I Format the load control is always active. It is not possible
to perform a reset, to program the second velocity characteristic, the
acceleration and brake delay and the parameters of the load control.