Page 38
programming the configuration variables (= CV). The CV programming
has been laid down for DCC decoders in the NMRA guidelines. The CV
programming for this Motorola decoder has been developed following
these guidelines, but differs in some points, according to the differences
between both formats. In particular programming the decoder on a
DCC programming-track is not possible.
Online programming
Alternatively to the CV programming it is possible to program the
address and the driving characteristics "online". This means:
§
Right after starting the programming mode your can enter the new
address and directly save it.
§
While programming the driving characteristics (starting and
maximum velocity, acceleration and brake delay) the locomotive is
running. By operating the speed knob the driving characteristics are
altered. As soon as these are set as desired, they can be saved
directly (online).
Restrictions in Motorola I format
The auxiliary functions F1, F2, F3 (switching on and off the acceleration
and brake delay) and F4 (switching on and off the shunting gear) are
not available in Motorola I format. Programming the decoder can only
be done via CV programming.
Technical specifications
Data format
Motorola I and II
Supply voltage
12-24 Volt digital voltage
Current consumption
(without connected loads)
approx. 10 mA
Max. current for motor
3.000 mA
Max. current per function output
1.000 mA
Max. total current
3.000 mA
Protected to
IP 00
Ambient temperature in use
0 - + 60° C