background image

tams elektronik

English

LC modules

LC-8 "Advertising light 4":  

Fusion of the advertising lights 1 to 3,

coming on one after the other. If the input JP2 is switched to earth, the
light sequence switches off after the completion of the active part of
the program. If the input JP2 is switched to earth, the light sequence is
interrupted.   If   the  input  remains   opens,   the   program   is   repeated
constantly.

LC-9 "Ignition module for gas lamps":  

If the input JP2 is given a

short electric  pulse (earth), the gas lamps start to flicker  and  grow
brighter   gradually.   Every   ignition   process   is   slightly   different.   After
approx.   5   seconds   the   gas   lamps   reach   their   maximum   brightness.
During  operation,  the  lamps  flicker  now  and  then  at  different  times
(variations of gas pressure). After the switch-off impulse,  (when the
input   JP2  is   given   a   short   electric   pulse)   all   lamps   shine   on   with
moderate brightness and go off completely in approx. 1.5 seconds.

LC-10 "Fluorescent tube simulator:

 If the input JP2 is given a short

electric pulse (earth), the different fluorescent tubes flicker for a moment
before all of them light one after the other - just like the real thing. The
turning on pattern is a little different for each. If the input JP2 is switched
to earth shortly, the  light   switches off.  When the input is switched to
earth permanently, a defective tube is simulated on output 1. This tube
flickers at irregular intervals, at times brightening quickly, at times slowly.

LC-11 "Occupied   house":  

Two   different   programs   are   available.

Program   1,   "Home",   starts   if   the   input   JP2   is  switched   to   earth,
Program 2, "Office",  if the input remains opens. The programs take
approximately 15 minutes and are repeated after a short pause.
Program 1: First the light in the kitchen (output 1) goes on for a while,
followed a bit later by the living room (output 2). Output 3 is assigned for
connecting a blue light bulb (the TV set), which flickers like a television
picture. Some time later the light in the kitchen switches off, and goes on
again once during the program flow. The light in the bathroom (output 4)

Page 12

Содержание LC Series

Страница 1: ...t a m s e l e k t r o n i k Manual Light Computer Item no 53 02015 53 02246 For all kits and ready built modules of the LC series tams elektronik n n n...

Страница 2: ...25 7 3 Connecting LEDs 26 7 4 Connecting the LC 16 30 7 5 Connecting the LC 24 31 8 Check list for troubleshooting 34 9 Guarantee bond 36 10 EU declaration of conformity 37 11 Declarations conforming...

Страница 3: ...ms in the future If you pass the kit or the ready built module on to another person please pass on the manual with it Intended use The LC modules are designed to be operated according to the instructi...

Страница 4: ...bling the kit you need an electronic soldering iron max 30 Watt or a regulated soldering iron with a fine tip and a soldering iron stand a tip cleaning sponge a heat resistant mat a small side cutter...

Страница 5: ...t consumption of more than 100 mA to output 1 a monostable relay 1xUm 12 V e g item no 84 61010 01 and a protective diode 1N400x x 2 LC module 18 a loudspeaker recommended impedance 32 Ohm e g item no...

Страница 6: ...ed impermissibly high humidity and condensation build up can cause serious injury due to electrical shock Take the following precautions to prevent this danger Never perform wiring on a powered module...

Страница 7: ...oldering always put the hot soldering iron in the soldering iron stand point the soldering iron tip carefully when soldering and remove liquid solder with a thick wet rag or wet sponge from the solder...

Страница 8: ...ering grease They contain acids that can corrode components and copper tracks Insert the component connecting pins into the PCB s holes as far as possible without force The components should be close...

Страница 9: ...soldering directly above the soldering joint with a side cutter After placing the parts please double check for correct polarity Check the PCB tracks for solder bridges and short circuits created by a...

Страница 10: ...n one after the other blink together three times and are switched off afterwards If the input JP2 is switched to earth the light sequence switches off after the completion of the program If the input...

Страница 11: ...aks can last for several minutes The patterns are different at all outputs which allows you to connect several work places The effect is most realistic when blue LEDs are connected to the outputs If t...

Страница 12: ...s LC 10 Fluorescent tube simulator If the input JP2 is given a short electric pulse earth the different fluorescent tubes flicker for a moment before all of them light one after the other just like th...

Страница 13: ...s they flash in changing sequences form running lights flicker irregularly etc The input JP2 has no function in this version LC 13 Candlelight simulator After switching on the module the candles start...

Страница 14: ...ient lighting LC 17 Speed trap The output 1 controls the speed trap which flashes at irregular intervals from approx 3 to 25 seconds The outputs 2 to 5 are assigned for connecting the flash lights of...

Страница 15: ...ed on After the interior light having been lighted the front and back lights and then the interior light are switched off Afterwards all lights are switched off for a period LC 19 Paparazzi flash The...

Страница 16: ...ly in the third cycle three outputs stay on and two continue to glow If the input JP2 is switched to earth the light sequence switches off after the completion of the active part of the program If the...

Страница 17: ...it is possible to connect to one or several outputs further LC modules to be switched delayed There are no restrictions concerning the number of LC 24 modules connected in series This allows to switch...

Страница 18: ...Protected to IP 00 Ambient temperature in use 0 60 C Ambient temperature in storage 10 80 C Comparative humidity allowed max 85 Dimensions of the PCB approx 25 x 30 mm Weight of the circuit approx 3 g...

Страница 19: ...pacitors they are polarized The value is given on the package Electrolytic capacitors are available with different voltage sustaining capabilities Using an electrolytic capacitor with a voltage sustai...

Страница 20: ...or abbreviated with the letters B E C in the circuit diagram Integrated circuits ICs Depending on the type ICs fulfil various tasks The most common housing form is the so called DIL housing from which...

Страница 21: ...itch DS 1 Light sensitive resistor R11 Assembly Proceed according to the order given in the list below First solder the components on the solder side of the PCB and then cut the excess wires with the...

Страница 22: ...own in the PCB layout 6 Solder pins 7 IC Insert the IC into the soldered socket Do not touch the IC without first discharging yourself by touching a radiator or other grounded metal parts Do not bend...

Страница 23: ...tructions below as well For the connection of the cables except JP2 you find socket terminal strips included in the package You can plug them onto the pin strips on the PCB and can remove them any tim...

Страница 24: ...1 LC 2 LC 3 LC 4 LC 5 LC 6 LC 8 LC 14 LC 15 LC 21 LC 22 LC 23 JP2 open endless repeat JP2 is connected to earth The cycle will be ended after the end of the program LC 7 JP2 open standard operation JP...

Страница 25: ...utputs e g by closing a switch 7 2 Connecting light bulbs As a rule you can connect one or two bulbs to one output Bulbs are not polarized Connect one side to the output the other to the return conduc...

Страница 26: ...the cathode to the output and the anode to the return conductor With wired versions the anode has the longer leg with SMD versions the cathode is marked e g by a reamed corner or a paint mark Caution...

Страница 27: ...t of 100 mA per output should not be exceeded In this case the output would be damaged Examples for parallel connection of LEDs Power supply Series resistors Current per LED max number of LEDs per out...

Страница 28: ...1 appr Forward voltage of the LED 2 Max number of LEDs 3 per output 12 V 17 V 2 V 7 4 V 3 16 V 22 V 2 V 10 4 V 4 18 V 25 V 2 V 11 4 V 5 1 Nominal voltage and operating voltage The operating voltage w...

Страница 29: ...r funfair lights best connect them as follows Connect so many LEDs in series as possible with the available operating voltage When using an a c transformer of 18 V you can connect 7 white or blue or 1...

Страница 30: ...tive resistor has to be placed that way it is exposed to the ambient light In order to set the sensitivity of the dim first set the trim pot to mid position and change the sensitivity as far as necess...

Страница 31: ...on have to be connected via a monostable relay 1xUm 12 V e g item no 84 61010 01 and a diode see connection diagram 7 5 Connecting the LC 24 Connecting cascaded LC 24 modules You can connect further L...

Страница 32: ...i k English LC modules You have to connect a diode 1N400x x 2 7 into the leads of cascaded LC 24 modules see connection diagram Observe the polarity of the diode The negative end of the diode is mark...

Страница 33: ...outputs of a LC 24 to switch them delayed You can use all LC modules except LC 9 and LC 10 When connecting a LC 16 you do not need the dim switch DS 1 You have to connect the LC modules via a monostab...

Страница 34: ...nnected to the module do not light Possible cause one or more components are soldered incorrectly Perform a visual check Possible cause A switch connected to the module is closed Check the position of...

Страница 35: ...repair is the difference between the price for the ready built module and the kit according to our valid price list We reserve the right to reject the repairing of a module when the repair is impossi...

Страница 36: ...uality of the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assemble...

Страница 37: ...alled by an authorised electrician Make no changes to the original parts and accurately follow the instructions connection diagrams and PCB layout included with this manual Use only original spare par...

Страница 38: ...t a m s e l e k t r o n i k English LC modules Page 38...

Страница 39: ...t a m s e l e k t r o n i k LC modules English Page 39...

Страница 40: ...n n Information and tips n http www tams online de n n n n Warranty and service n Tams Elektronik GmbH n Fuhrberger Stra e 4 DE 30625 Hannover n fon 49 0 511 55 60 60 fax 49 0 511 55 61 61 n e mail m...