background image

t

a

ms elektronik

ABC-1

1. Getting started

The instructions will help you step by step with the safe and proper installation and use of
your brake module. Before you start to put the brake module into operation, read this manual
completely,   especially  the  safety  instructions  and  the  section   on  possible  errors  and  their
elimination. You will then know what you have to pay attention to and thus avoid errors that
sometimes can only be rectified with a lot of effort. 
Keep the instructions in a safe place so that you can restore functionality later in the event of
any   malfunctions.   If   you   pass   the   brake   module   on   to   another   person,   also   give   the
instructions with it.

1.1. Contents of the package 

Turnout decoder WD-34:

1 brake module ABC-1  (item no. 49-03106-01)

1 plastic spacer

1.2. Accessories

Connection cables

The use of stranded wire is recommended for making the connections. Stranded wires consist
of several thin individual wires and are therefore more flexible than rigid wires with the same
copper cross-section. Recommended cross-sections: 

for all connections: > 0.25 mm²

1.3. Intended use 

The   brake   module   is   intended   for   use   in   model   construction,   especially   in   model   railway
layouts, according to the specifications in the manual. Any other use is not in accordance with
the intended use and will result in the loss of the warranty claim. Intended use also includes
reading, understanding and following all parts of the instructions. The brake module is not
intended to be used by children under the age of 14. 

1.4. Safety instructions

Improper use and non-observance of the instructions can lead to incalculable hazards. Prevent
these dangers by carrying out the following measures:

Only use the brake module in closed, clean and dry rooms. Avoid moisture and splash water
in   the   environment.  After   condensation   has   formed,   wait   two  hours  for   acclimatisation
before use. 

Disconnect the brake module from the power supply before carrying out wiring work. 

Supply the brake module only with extra-low voltage as specified in the technical data. Use
only tested and approved transformers.

Only plug the mains plugs of transformers into properly installed and fused earthed sockets.

When making electrical connections, ensure that the cable cross-section is sufficient.

Heating of the brake module during operation is normal and harmless. 

Getting started | 3

Содержание ABC-1

Страница 1: ...ABC 1 Brake module for the ABC braking method Manual Item number 49 03106 tams elektronik n n n...

Страница 2: ...Declaration of Conformity 11 6 3 Declarations on the WEEE Directive 11 Version 1 0 Status 09 2023 Tams Elektronik GmbH All rights reserved in particular the right of reproduction distribution and tran...

Страница 3: ...m 1 3 Intended use The brake module is intended for use in model construction especially in model railway layouts according to the specifications in the manual Any other use is not in accordance with...

Страница 4: ...on on the maximum operating temperature in the technical data Regularly check the operational safety of the brake module e g for damage to the connection cables If you notice damage or if malfunctions...

Страница 5: ...ing section In principle the braking section is only effective for one direction of travel at a time When travelling in the opposite direction the locomotive does not react to the braking section Whil...

Страница 6: ...switch The brake module is bridged with a switch to trigger the continuation of a train after it has stopped or to let a train pass without stopping As a switch you can use a separate switch if you w...

Страница 7: ...k the CV settings if the ABC braking method is active and if the ABC detection is inverted The output voltage of the booster is not symmetrical If possible change the ABC sensitivity of the decoder in...

Страница 8: ...g out the repair s By sending in the product s you give us the order to inspect and repair it We reserve the right to refuse the repair if it is technically impossible or uneconomical In the event of...

Страница 9: ...t and water Environment For use in closed rooms Ambient temperature during operation 0 30 C Permissible relative humidity during operation 10 85 non condensing Ambient temperature during storage 10 40...

Страница 10: ...f the components as well as the function of the parts according to the parameters in not mounted state We guarantee the adherence to the technical specifications when the kit has been assembled and th...

Страница 11: ...product is subject to the requirements of the EU Directive 2012 19 EC on Waste Electrical and Electronic Equipment WEEE i e the manufacturer distributor or seller of the product must contribute to th...

Страница 12: ...er Information and Tips http www tams online de Warranty and Service tams elektronik GmbH Fuhrberger Str 4 30625 Hannover GERMANY Phone 49 0 511 55 60 60 Fax 49 0 511 55 61 61 Email support tams onlin...

Отзывы: