Multi-Timer
Connection to the outputs (operation modes 1, 2 and 3)
The Multi-Timer works like a switch. It does not provide current for the
operation of downstream circuits at it´s outputs. That is why these
need an external voltage supply (d.c. or a.c.).
When using the Multi-Timer with operation modes 1, 2 or 3 (as time
switch, pulse delay or ramdom switch), connect the downstream
circuits to the four outputs according to your needs.
Connection to the switching inputs (operation modes 1 and 2)
As soon as the contacts of the switching inputs are closed, the
switching operations will be released at the related outputs.
For the operation modes 1 or 2 you have to connect push-buttons to
the switching inputs. As an alternative you can mount upstream circuits
releasing a short switching pulse – like push-buttons.
Connection to the switching inputs (operation mode 3)
In order to affect the random control manually, you have to connect
switches (or circuits with a similar mode of operation) to the switching
inputs. As soon as the contacts of the switching inputs are closed, the
previously by the random switch set state will be "frozen".