3.5 White Balance
White Balance has the following modes, all of which can be set by using VISCA
Command (CAM_WB Command).
⚫
Auto White Balance (AWB)
AWB has two modes, ATW1 (Narrow) and ATW2 (Wide).
ATW1 (Narrow)
This covers about 7000K to 2500K color temperature.
ATW1 is factory default setting.
ATW2 (Wide)
This covers about 10000K to 2200K color temperature.
⚫
Manual WB
R gain (CAM_RGain Command) 256 steps and B gain (CAM_BGain command) 256 steps
can be set manually.
⚫
Fixed Color Temperature mode
Two fixed color temperature modes:
INDOOR
Fixed color temperature for indoor use. (about 3200K)
OUTDOOR
Fixed color temperature for outdoor use. (about 5800K)
⚫
One Push Trigger
After having taken the image of white paper throughout a screen, please issue One
Push Trigger Command in CAM_WB Command. White balance is calculated and
shifts to One Push WB mode.
⚫
One Push WB
The One Push White Balance mode is a function to photograph a subject with a
fixed white balance mode that use generated WB data by the latest One Push
Trigger.