Bend the duct at a gentle angle, avoiding a sharp 90 degree corner, and slide the duct collar over the 
transition duct. Make sure to maintain the 10” diameter of the duct throughout the bend to ensure 
proper airflow.  Connect the duct to the inlet collar of the fan

 

6)

 

Plug the power cord into a 115 Volt switched outlet that has been wired to local codes and standards.  
This outlet may be switched from a remote location.   

Operation 

Important 

- Be sure at least one window is open when the fan is operating. 

 

1.

 

Turn the wall switch to ON. The fan will start and the damper will open. 

2.

 

Turn the wall switch to OFF. The fan will stop and the damper will close.   
    When the fan rotation has slowed the magnet will pull the damper closed. 

 

Care 

 

The motor in 

The

 

Infinity 1100 CQ

 is permanently sealed and does not require oiling. To keep dirt, dust 

and debris from the fan we recommend that you periodically clean the grille from within the living space 
and dust the fan blades from within the attic. Please remember to make sure that the fan is OFF before 
dusting the fan blades. 
 

Troubleshooting 

 

The most common problem with 

The

 

Infinity 1100 CQ

 is caused by incorrect wiring. Verify the switched 

outlet has 115 Volts. 

 

 
 

 

Specifications 

 

Electrical Requirements: 

Air Flow: 

Duct Size: 

Duct Collar Length: 

Duct Length: 

Interior Grille Dimensions: 

Transition Duct Dimensions: 

Mounting Flange Dimensions: 

Overall Dimensions: 

Overall Dimensions w/Damper Open: 

Unit Weight: 

 
115V, 60Hz, 1.5A 
1070 cfm @ .1

"

 Wg 

10” 
3

"

 with Bead 

6 ft. 
14

"

 x 14

"

 

10

"

 Dia x 14

"

Sq x 10

"

14-1/4

"

 x 1-1/2

16-1/4

"W

 x 16

"

H x 6-1/4

"

13

"

 

13 lbs. 
 

 

 

 

 

 

320 Main Street / Buzzards Bay, MA 02532 

508-759-4660 / 800-222-5932 / Fax 508-759-6001

 

Содержание INFINITY 1100 Cool & Quiet

Страница 1: ... questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting cannot be locked securely fasten a prominent warning device such as a tag to the service panel When cutting or drilling into wall or ceiling do not damage electrical wiring or other hidden ...

Страница 2: ...ter Caulking Duct Tape 1 Attach the mounting brackets to the fan with the nuts and bolts provided The wiring box should be positioned for easy access 2 Using the wood screws provided attach the mounting brackets to a rafter or support beam at the selected location The housing must hang plumb to allow the damper to close completely 3 Install the interior grille a Move any insulation out of the way ...

Страница 3: ...Care The motor in The Infinity 1100 CQ is permanently sealed and does not require oiling To keep dirt dust and debris from the fan we recommend that you periodically clean the grille from within the living space and dust the fan blades from within the attic Please remember to make sure that the fan is OFF before dusting the fan blades Troubleshooting The most common problem with The Infinity 1100 ...

Страница 4: ...ORTH ABOVE NO EXPRESS OR IMPLIED WARRANTY IS GIVEN OR AUTHORIZED BY TAMARACK TECHNOLOGIES INC AND ALL OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED ANY WARRANTY OR MERCHANTABILITY OF FITNESS FOR ANY PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER MOREOVER ANY LIABILITY OF TAMARACK TECHNOLOGIES INC FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT VALUE OF THE PRODUCT IN NO EVENT S...

Отзывы: