background image

 
The Best Location for the Infinity1100 CQ 

 
 

When selecting fan mounting location, consider the following:  

· Mounting the fan as far as possible from the interior air intake or exhaust points will 
minimize fan operating noise from being transmitted back through the duct-work.  
· The fan location should allow sufficient access for service.  
· Allow sufficient room for the damper to swing open. 
 

When selecting interior grille location, consider the following:  

·The interior grille should be installed in a central location within your home.  Above a central hallway or at 
the top of a stairwell will provide the best airflow. If desired, the grille can be mounted vertically.

  

 
Installation 

 

DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED.  MAKE SURE ELECTRICAL 
SERVICE TO THE FAN IS LOCKED IN "OFF" POSITION. 
 
 

 
What you will need: 
 

Make sure that you have adequate exhaust area out of your attic. This can be accomplished with a 
combination of roof, ridge or gable end vents. 

The

 

Infinity 1100 CQ 

requires a minimum of three (3) 

square feet of attic exhaust area. 
 

* Drill and Drill Bits    *Phillips Head Screwdriver    *Drywall Cutter    *Caulking    *Duct Tape 

 

 

 

1)

 

Attach the mounting brackets to the fan with the nuts and bolts provided. The wiring box should be 
positioned for easy access.  
 

2)

 

Using the wood screws provided, attach the mounting brackets to a rafter or support beam at the 
selected location. The housing must hang plumb to allow the damper to close completely. 

 

3)

 

Install the interior grille.  

 

a)

 

Move any insulation out of the way to expose the sheetrock surface.   

b)

 

Using the transition duct as a template, mark the opening into the living area.   

c)

 

Remove the sheetrock within the mark with a drywall cutter.  

d)

 

Place a bead of caulking around the transition duct flange and place it into the opening. The 
caulking will prevent air from travelling between the attic and the living space. 

e)

 

From below, position the interior grille to cover the opening.  Drill pilot holes through the grille, 
through the sheetrock and into the transition duct.  

f)

 

With the screws provided, attach the grille to the transition duct, sandwiching the sheetrock in 
between. 

 

4)

 

Connect the duct to the inlet collar of the round to square transition duct using clamps or duct tape.  It 
is recommended that the inner vinyl core of the insulated duct be clamped or taped to the collars and 
that the vapor barrier surrounding the insulation be duct taped to the housing. 

 

(cont’d) 

 
 

Содержание INFINITY 1100 Cool & Quiet

Страница 1: ... questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting cannot be locked securely fasten a prominent warning device such as a tag to the service panel When cutting or drilling into wall or ceiling do not damage electrical wiring or other hidden ...

Страница 2: ...ter Caulking Duct Tape 1 Attach the mounting brackets to the fan with the nuts and bolts provided The wiring box should be positioned for easy access 2 Using the wood screws provided attach the mounting brackets to a rafter or support beam at the selected location The housing must hang plumb to allow the damper to close completely 3 Install the interior grille a Move any insulation out of the way ...

Страница 3: ...Care The motor in The Infinity 1100 CQ is permanently sealed and does not require oiling To keep dirt dust and debris from the fan we recommend that you periodically clean the grille from within the living space and dust the fan blades from within the attic Please remember to make sure that the fan is OFF before dusting the fan blades Troubleshooting The most common problem with The Infinity 1100 ...

Страница 4: ...ORTH ABOVE NO EXPRESS OR IMPLIED WARRANTY IS GIVEN OR AUTHORIZED BY TAMARACK TECHNOLOGIES INC AND ALL OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED ANY WARRANTY OR MERCHANTABILITY OF FITNESS FOR ANY PARTICULAR PURPOSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER MOREOVER ANY LIABILITY OF TAMARACK TECHNOLOGIES INC FOR THE PRODUCT SHALL BE LIMITED TO THE REPLACEMENT VALUE OF THE PRODUCT IN NO EVENT S...

Отзывы: