45
Product name: DOWFROST
™
Heat Transfer Fluid
Issue Date:
04/09/2015
Page 3 of 10
Advice for firefighters
Fire Fighting Procedures:
Keep people away. Isolate fire and deny unnecessary entry. Use water
spray to cool fire exposed containers and fire affected zone until fire is out and danger of reignition has
passed. Fight fire from protected location or safe distance. Consider the use of unmanned hose
holders or monitor nozzles. Immediately withdraw all personnel from the area in case of rising sound
from venting safety device or discoloration of the container. Burning liquids may be extinguished by
dilution with water. Do not use direct water stream. May spread fire. Move container from fire area if
this is possible without hazard. Burning liquids may be moved by flushing with water to protect
personnel and minimize property damage.
Special protective equipment for firefighters:
Wear positive-pressure self-contained breathing
apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers,
boots, and gloves). If protective equipment is not available or not used, fight fire from a protected
location or safe distance.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures:
Use appropriate safety
equipment. For additional information, refer to Section 8, Exposure Controls and Personal Protection.
Environmental precautions:
Prevent from entering into soil, ditches, sewers, waterways and/or
groundwater. See Section 12, Ecological Information.
Methods and materials for containment and cleaning up:
Small spills: Absorb with materials such
as: Cat litter. Sawdust. Vermiculite. Zorb-all®. Collect in suitable and properly labeled containers.
Large spills: Dike area to contain spill. Recover spilled material if possible. See Section 13, Disposal
Considerations, for additional information.
7. HANDLING AND STORAGE
Precautions for safe handling:
No special precautions required. Keep container closed. See
Section 8, EXPOSURE CONTROLS AND PERSONAL PROTECTION.
Spills of these organic materials on hot fibrous insulations may lead to lowering of the autoignition
temperatures possibly resulting in spontaneous combustion.
Conditions for safe storage:
Do not store in: Galvanized steel. Opened or unlabeled containers.
Store in original unopened container. See Section 10 for more specific information. Additional storage
and handling information on this product may be obtained by calling your sales or customer service
contact.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure limits are listed below, if they exist.
Component
Regulation
Type of listing
Value/Notation
Propylene glycol
US WEEL
TWA
10 mg/m3
Exposure controls