background image

V S   H A R D W A R E   S P E C I F I C A T I O N   G U I D E

1

I N T RO D U C T I O N

The phone system you have purchased is designed and supplied to meet the technical standards for use in 
specific countries and for connection to the major telephone service providers in those countries. It is 
subject to regulatory certification and compliances. 

WHAT YOU SHOULD KNOW

While the phone system is customer installable, certain skills are required if you need to route cables or to 
configure a network. The following points will help you determine the required skills:

Configuring the system using the Management software can be performed by anyone with basic 
computer skills once the system is physically installed with proper networking equipment 
configurations (if two or more units are networked on a LAN).

While most buildings are wired to accommodate the system setup, the need to route telephone and/or 
network cabling can occur occasionally. If your organization does not have someone with this skill 
set, we recommend the use of an outside telephony system technician.

You may need to connect the system to network equipment such as a router, switch or hub with a 
connection to the Internet, and to configure a firewall, computer and the system for networked use 
internally and with Internet. If your organization does not have someone with this IT skill set, we 
recommend the use of an outside IT technician.

If you are installing a single, non-VoIP system, anyone with basic computer skills can use the 

TalkSwitch 

Start Guide

 and this guide to perform a full installation and configuration.

Phone system installations can be categorized into some general configurations, such as single unit 
installation, networked units installation, VoIP or non-VoIP installation, etc. This section helps you 
determine your best possible plan of action using this guide, according to your installation type. While 
not every possible installation scenario is detailed below, determine which one better fits your situation 
and use its guidelines as a starting point. For solutions to common problems, please refer to Chapter 6: 

Troubleshooting and Support 

in the 

TalkSwitch User Guide

.

IMPORTANT INFORMATION

Electrical shock

Do not open the enclosure, except as instructed to install an upgrade kit. When installing an upgrade kit, 
disconnect the power adapter and all other cables before removing the enclosure cover, and replace the 

cover b

efore reconnecting the power adapter.

Do not expose the system to any liquids; that can pose a risk of electrical shock.

Содержание owner friendly

Страница 1: ...The owner friendly phone system for small business VS Hardware Specification Guide...

Страница 2: ...are FortiManager FortiAnalyzer and TalkSwitch are registered trademarks of Fortinet Inc and other Fortinet names herein may also be registered trademarks and or common law trademarks of Fortinet Other...

Страница 3: ...Specifications 3 Analog Extension Specifications 4 Telephone Line Specifications 4 Dimensions 4 Weight 4 Regulatory Approvals 5 VoIP Features models with VoIP lines only 5 INSTALLATION 6 Upgrading sy...

Страница 4: ...INFORMATION 15 Safety Precautions 15 External audio source isolation 15 Important Notices 16 CE Compliance 16 FCC and IC Warnings 16 FCC Part 15 16 ACTA TIA EIA IS 968A FCC Part 68 and IC CS 03 17 DOC...

Страница 5: ...ion to the Internet and to configure a firewall computer and the system for networked use internally and with Internet If your organization does not have someone with this IT skill set we recommend th...

Страница 6: ...each phone system will connect extension E4 to phone Line 1 to permit calls except AU models Calls must be dialed without a hunt group All other system functions will not be available until power is...

Страница 7: ...4 4 VoIP ports 0 4 8 0 4 8 VoIP numbers 0 12 24 0 12 24 Local extensions Analog and IP 16 expandable to 24 16 expandable to 24 16 expandable to 24 16 expandable to 24 16 expandable to 24 16 expandabl...

Страница 8: ...25 Hz depending on region True sine wave Total ringing load 5 REN Connector type RJ 11 2 pin Trunk type Loop start Interface impedance Configurable 600 600 complex 900 900 complex Ringing impedance 3...

Страница 9: ...adapter complies with UL and CSA Reduction of Hazardous Substances RoHS Directive 2002 95 EC VOIP FEATURES models with VoIP lines only Embedded SIP server and user agents Integrated registrar Fax tone...

Страница 10: ...he front panel consists of a power button 4 line lights and the power data light Light State Description Line 1 to Line 4 On Line is in use Flickering Line is ringing Pulsing slowly Line caller is on...

Страница 11: ...s to show system activity and diagnostic conditions as described in Chapter 6 of the TalkSwitch User Guide Unit back panel The PF box between E4 and L1 represents power failure support In the event of...

Страница 12: ...cesses can also be applied to multi line wiring Single line wiring For a single telephone line all phones in the building will usually be wired using the RED and GREEN wires of the phone cord The othe...

Страница 13: ...may be located near the fuse box Wiring The box will contain at least four posts used to branch the incoming wiring to the internal phone wiring The RED post should have all the RED wires attached to...

Страница 14: ...mes in Home phones do not have phone system functionality and rely on phone company features for any enhancements System phones separate from home phones Advantages Easy to set up May not require any...

Страница 15: ...s single line phone cords 2 pins Using a two line phone two line phone cord 4 pins Connecting to the rear panel wall jack to the phone system L1 This shows a single line from If you have two lines you...

Страница 16: ...ffice phones including voicemail call cascade mode scheduling call forwarding etc Suitable for one or two incoming phones lines Disadvantages Requires a little more wiring and additional cabling Re wi...

Страница 17: ...Adding an extension block 1 Add an extension block next to the demarcation point 2 Connect the house loops and the phone cable from the demarcation point to the posts of the extension block D E 111 11...

Страница 18: ...se a single line phone cable from the demarcation point to jack L1 rear panel To extension block use a single line phone cable from jack E4 Ext 113 To fax machine optional from jack E3 Ext 112 To phon...

Страница 19: ...the type described in the operating instructions or marked on the equipment Use only the power adapter supplied with the system 7 Damage requiring service Do not attempt to service the system yourself...

Страница 20: ...vice FCC Part 15 This equipment has been tested and found to comply with the limits for a CLASS B Digital Device pursuant to Part 15 of the FCC rules These limits are designed to provide a reasonable...

Страница 21: ...etermine the quantity of devices that may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call In most but not...

Страница 22: ...2 95 EC The RoHS directive provides for restriction or elimination of the following substances Lead mercury cadmium hexavalent chromium polybrominated biphenyls PBB and polybrominated diphenyl ether P...

Отзывы: