OY1210 LoRaWAN CO2 meter, User manual, Version 1.0
11
6
Specification
Operating principle
Non-dispersive infrared (NDIR)
Yes
Sample method
Diffusion
Accuracy and range
Temperature accuracy
± 0,2 °C (conditions 0 °C to +50 °C)
Temperature range
-20 °C to +60 °C
Humidity accuracy
± 2% (conditions 10-90% RH)
Humidity range
0% to 100% non-condensing
Measurement range CO
2
400
–
5000 ppm
Accuracy CO
2
±50ppm ±3% of reading
RMS noise CO
2
0.7ppm @ 400ppm
1.4ppm @2000ppm (filtered)
Connectivity
Network
LoRaWAN
Frequency bands
868 MHz
Provisioning
Over the air & personalization
Size
Size
111 x 77 x 26 mm
Weight
136g
Security
Algorithms
AES-128
Hardware
Cryptographic co-processor
Features
Secure boot
Secure firmware upgrade
Hardware based ultra-secure key storage
Battery life
Battery life length