![Talkpool 0786767169876 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/talkpool/0786767169876/0786767169876_user-manual_815230019.webp)
OY1110 LoRaWAN Temperature and humidity sensor, User manual, Version 1.0
19
9.6
Uplink query response
When communication on LoRaWAN port 1 the following header is used:
Uplink command device => network
Field
Bytes Value
Description
Note
Type
1
xx
0x01: Data
0x02: Command NACK
Index
1
xx
Command Index
Data
As defined for Command Index (only for Type: Data)
9.6.1
Uplink status report
The uplink status report is sent unsolicited during
Configure
state and queried in
Operational
state.
Example:
Port 1: 01 20 00
01: Data type
20: Status command
00: Normal startup
For non-zero data, an error has occurred. Provide the error code in contacts with
Talkpool support.