The information contained herein may be changed by Deeco Services without notice. Deeco Services shall not be held liable for any errors
National Service and Supply Centre
35 Wakefield Street, Alicetown 5010
www.deeco.co.nz
The Flush Mode
OFF-By time - No flushing will take place.
DP- Flushing will be triggered by DP only.
The Flush Mode defines how the flushing cycles is triggered. The selectable options are as
follows:
In this case, the flushing cycles will be repeated in a selected interval or will be triggered by
the DP signal depending on which happens first. No matter how the flushing cycle started,
the interval to the next cycle will start to be measured again after each ending of flushing
sequence. The selectable intervals are as follows:
5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 minutes
2, 3, 4, 5, 6, 8, 12, 18, 24, 72, 120 hours
If the “+” and “-“ keys are pressed and held down simultaneously the “Flush Mode”
field will show the left time until next cycle, alternately hours and minutes.
The Accumulations
The unit accumulates and displays the number of flushing cycles caused by DP, by time, or
manually At each of the accumulation fields, the “+” or “-“ keys may be used for clearing
the accumulated value.