background image

 

 

 

1

 

FILTRON 1-10 (DC/AC) 

List of features   

 

  The 

“FILTRON  1-10”  is  a  modular  backflushing  controller  for  automatic  filters  of  1  to  10 

stations.  

  There exist DC and AC models.  
  The  DC  model  can  be  powered  either  by  6v  DC  or  12v  DC  and  it  activates  2  wired  12v  DC 

latching solenoids. The voltage for the solenoids switching is boosted by a charge pump. 

  The  AC  model  contains  an  internal  transformer  that  can  be  powered  by  110v  or  220v  from 

which it generates the 24v AC for the solenoids.  

  Flushing  cycles  may  be  triggered  either  by  time  or  by  the  embedded  electronic  DP  sensor 

reaching the set point, or by a dry contact signal from an external DP sensor. 

 

Endless  looping  problems  can  be  eliminated  by  detecting  repeated  consecutive  cycles 
passing beyond a predefined limit.

 

 

The unit can optionally handle a Pressure-Sustaining / Main valve, and an Alarm output.

 

 

The unit is equipped with a customized LCD display and key board.

 

 

The  unit  counts  separately  the  number  of  flushing  cycles  triggered  by  DP,  by  time  and 
manually.

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание FILTRON 1-10 AC

Страница 1: ...D NAAMAN CENTER HAIFA ACCO ROAD 7000 P O BOX 775 KIRYAT MOTZKIN 26119 ISRAEL TEL 972 4 8775947 972 4 8775948 FAX 972 4 8775949 E mail talgil33 netvision net il FILTRON 1 10 DC AC U S E R S M A N U A L...

Страница 2: ...red by 110v or 220v from which it generates the 24v AC for the solenoids Flushing cycles may be triggered either by time or by the embedded electronic DP sensor reaching the set point or by a dry cont...

Страница 3: ...blinking Once entering this process of passing through the editable fields the user has no way back but by pushing the ENTER key repeatedly he passes through the chain of editable fields until arrivin...

Страница 4: ...Flush Mode The Flush Mode defines how the flushing cycles is triggered The selectable options are as follows OFF no flushing will take place By time In this case the flushing cycles will be repeated...

Страница 5: ...e selectable delay steps are 5 10 15 20 25 30 35 40 45 50 55 sec 1 1 5 2 2 5 3 3 5 4 4 5 5 5 5 6 min Dwell time the delay between stations can be set to 5 10 15 20 25 30 35 40 45 50 55 or 60 sec DP de...

Страница 6: ...es the flushing sequence will start from the beginning rather than continue from the stop point Connecting the DP sensor to the filter system The DP sensor is connected to the filter system by 2 comma...

Страница 7: ...1 Valve 2 Pre Dwell Flush time Valve 3 Valve 4 Dwell time Main valve Valve 1 Valve 2 Pre Dwell Flush time Valve 3 Valve 4 Delay valve Dwell time V V Valve Delay Timing Diagram Without Delay Valve Inc...

Страница 8: ...at 1 The External DP sensor is optional and it is intended for use in cases there is no Embedded Electronic DP included 2 The powering of the unit can be either by 6v DC or 12v DC 3 The solenoids will...

Страница 9: ...External DP sensor is optional and it is intended for use in cases there is no Embedded Electronic DP included 2 The powering of the unit is by 24VAC transformed from 220 110 VAC 3 The solenoids will...

Страница 10: ...Embedded electronic analog DP sensor or external dry contact DP sensor Pressure Sensor Dry contact pressure sensor Operating temperature 0 60 C AC MODEL Power source 220 or 110 v AC 50 or 60 Hz with...

Отзывы: