background image

    

INSTALLATION  MANUAL FOR CRYSTALLINE SOLAR PHOTOVOLTAIC MODULES 

     

Version: A2         Effective Date: May 13, 2015 

 

ZHONGLI TALESUN SOLAR COMPANY LIMITED 

Address: No. 1 Talesun Road, Changkun Industrial Park, Shajiabang Town, Changshu, Suzhou, Jiangsu Province, 215542, P.R.China 

Website: 

www.talesun.com

    Email: 

[email protected]      

 Tel: +86 400 885 1098 

13 / 19 

 

 

5

 

COMMISSION AND MAINTENANCE 

 

5.1

 

BLOCKING DIODES AND BYPASS DIODES  

 

Blocking diodes prevent current flowing from the battery to the module when no electricity is being generated. It is 
recommended to use blocking diodes when a charging regulator is not used. Your specialist dealer can advise you 
regarding the suitable types. 

 

In systems with more than two modules in series, high reverse current can flow through cells that are shaded partially 
or outright when part of a module is shaded and the rest is exposed to the sun. These currents can cause the affected 
cells to get very hot and could even damage the module. To protect module from such high reverse currents, by-pass 
diodes are used in modules. All modules rated greater than 55 Watt have bypass diodes already integrated in the 
junction box. In the unlikely event of diode failure, it can be easily replaced; however, doing so will void warranty 
unless this exchange is made by an authorized person. 

 

Protect yourself from electric shocks while debugging or maintaining the solar power system. 
 

5.2

 

TROUBLESHOOTING 

DANGER!  Life danger due to electric shock!

 

 

 

Please do not attempt to correct problems on your own! 

 

In case of problems or damaged modules (for example, glass breakage, damaged cables) 
please contact your installer or the Talesun Technical Customer Service. 

 

5.3

 

MAINTENANCE 

Talesun modules are built to last and require minimal maintenance. The dirt is typically washed away by rain. However, rain 
may not adequately clear more stubborn grime (i.e. pollen, vegetation, bird droppings, etc.). Such soiling which shades the 
active  area  of  the  module  can  lead  to  a  reduction  in  the  system‘s  performance.  Talesun  recommends  the  following 
maintenance in order to ensure optimum performance of the module: 

 

Clean the glass surface of the module as necessary. Always use water and a soft sponge or cloth for cleaning. A mild, 
non-abrasive cleaning agent can be used to remove stubborn dirt. 

 

Check the electrical and mechanical connections every six months to verify that they are clean, secure and undamaged. 

 

If any problem arises, have them investigated by a competent specialist. Attention: observe the maintenance 
instructions for all components used in the system, such as support frames, charging regulators, inverters, batteries 
etc.  

 

 

Содержание TP572M-170

Страница 1: ...kun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 INSTALLATION MANUAL For crystalline solar phot...

Страница 2: ...POSE OF THE MANUAL 1 2 DISCLAIMER OF LIABILITY 1 3 PRODUCTION IDENTIFICATION 2 SAFETY GUIDELINES 2 1 GENERAL SAFETY GULDELINES 2 2 PRODUCT PRECAUTION 2 3 TRANSPORT AND STORAGE SAFETY GUIDELINES 3 MECH...

Страница 3: ...f the solar installation Information for operators Keep these instructions safe for the entire useful life of the solar installation Please contact your plant supplier for information concerning the f...

Страница 4: ...eries Cover the solar modules with opaque material for the entire duration of assembly Only then is the module reliably de energized Never disconnect plugs when under load Be aware that even without t...

Страница 5: ...es or improper storage Ensure modules do not bow under their own weight Do not rest a module unprotected on its edges This can damage the module and the frame Do not lift or move the modules using the...

Страница 6: ...stem The modules may be installed in landscape or portrait format Install the module in such a way that the junction box is positioned in the upper area of the module and the wires hang downwards The...

Страница 7: ...frame Modules should be bolted to support structures through mounting holes located in the frame s back flanges only Do not drill additional holes Doing so will void the warranty Each module must be s...

Страница 8: ...ructions above b Clamping installation Modules can be installed with clamps Modules must be securely attached to the mounting structure with four clamps on the long frame The modules must be properly...

Страница 9: ...990mm 40mm 2400Pa 250mm 100mm 5400Pa 250mm 100mm TP648 series 1324mm 990mm 35mm 2400Pa 200mm 100mm 5400Pa 200mm 100mm 1324mm 990mm 40mm 2400Pa 200mm 100mm 5400Pa 200mm 100mm TP572 series 1580mm 808mm...

Страница 10: ...nsure that the construction or structure roof facade support etc where the modules are being installed is strong enough to support the weight of the modules and all other system components If modules...

Страница 11: ...ed There is no preparation required Spacing Care must be used to avoid interference between adjacent grounding clips and other components for removal of the grounding clip Removal The wire can be remo...

Страница 12: ...rsion A2 Effective Date May 13 2015 ZHONGLI TALESUN SOLAR COMPANY LIMITED Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website w...

Страница 13: ...Date May 13 2015 ZHONGLI TALESUN SOLAR COMPANY LIMITED Address No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Ema...

Страница 14: ...ever doing so will void warranty unless this exchange is made by an authorized person Protect yourself from electric shocks while debugging or maintaining the solar power system 5 2 TROUBLESHOOTING DA...

Страница 15: ...Mono crystalline 5inch 72cells Mono crystalline Dimension mm 1960 990 40 1960 990 45 1960 990 50 1640 990 35 1640 990 40 1580 808 35 1580 808 40 Weight kg 24 19 14 7or15 Module Type TP672P TP660P TP6...

Страница 16: ...290 1000 IEC 290 36 4 7 97 45 3 8 63 TP672M 285 1000 IEC 285 36 2 7 88 45 2 8 53 TP672M 280 1000 IEC 280 36 2 7 74 45 1 8 41 TP660M 275 1000 IEC 275 31 1 8 85 38 3 8 95 15 TP660M 270 1000 IEC 270 31 8...

Страница 17: ...290 35 9 8 09 44 7 8 72 TP672P 285 1000 IEC 285 35 8 7 97 44 6 8 65 TP672P 280 1000 IEC 280 35 7 7 86 44 5 8 56 TP672P 275 1000 IEC 275 35 5 7 76 44 4 8 49 TP672P 270 1000 IEC 270 35 4 7 64 44 3 8 4 T...

Страница 18: ...215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 17 19 TP572M 205 1000 IEC 205 37 5 5 49 45 7 5 92 TP572M 200 1000 IEC 200 37 3 5 42 45 5 5 85 TP572M 195 1000 IEC...

Страница 19: ...86 400 885 1098 TEL 86 512 8235 5888 FAX 86 512 8235 5588 JAPAN 6F 3 22 1 Toranomon Minato ku Tokyo Japan 105 0001 Email japan talesun com Web www talesun com jp T 03 5733 3498 F 03 34341515 USA 111 W...

Страница 20: ...s No 1 Talesun Road Changkun Industrial Park Shajiabang Town Changshu Suzhou Jiangsu Province 215542 P R China Website www talesun com Email sales talesun com Tel 86 400 885 1098 19 19 THAILAND Thai C...

Отзывы: