Ntegra
Process Instructions
TP05413021 Interim
Page 17 of 56
Copyright © 2009 by Talaris Ltd., Basingstoke (UK)
4
Process Instructions
4.1
Piece Count
Piece count may be used to count notes that do not have currency data installed
in the Ntegra.
Piece count may performed either with or without a batch setting, however, if no
batch is set, the count will stop when the stacker or reject pocket reaches full
capacity.
Using the “UP” navigation key, set the Ntegra in the “Count” mode.
If required, press the BATCH key to enable the batch limit. If a quantity other than
the default batch limit is required, enter the batch limit using the numeric keys,
followed by the ENTER key.
Select AUTO or MANUAL start mode.
Place the notes to be counted on the input hopper. In the AUTO mode, the
Ntegra will start as soon as notes are placed on the input hopper. With the Ntegra
in the MANUAL mode, press the START/STOP key to commence the count.
The Ntegra will count the notes, and display the total.
If the batch ( or reject pocket ) limit is reached, the Ntegra will stop. Remove the
notes from the full pocket. If AUTO was selected, the Ntegra will re-start
automatically. If MANUAL was selected, press the START/STOP key to re-
commence the count.
Note:
In the COUNT mode, all detectors are disabled.