background image

1.0V most correspond to approx.10m.

 Ex)1.25V ⇒ 12.5m

   2.87V ⇒ 28.7m

   4.00V ⇒ 40.0m

2  Distance check

3  Light reception level check

5

5

1.25V

12.5m

1.50V

15m

1.00V

10m

Ex)When the distance from the sensor to the reflector is 15 m

Beam on protection

line

Beam reflected

on objects

To be readjusted

IMPORTANT

10m

15m

⑤Replace the cover and tighten the fixing screw.

    Once the cover is fixed, the unit automatically

    starts adjusting the transmission power

    with short pip sound.

    Be careful not to block the optical unit

    (protection line) with your body or hands

    until pip sound stops.

    (It may take max. 10 sec.) 

If pip sound stops, the optical axis adjustment is completed.

In case pip sound continues, go back to [

2. Distance check

]

and do the setting again.

①Ensure that the monitor output changeover switch is set to

    "Distance".     When adjusting the optical axis by changing the

    installation distance, long press the distance setting button

     (short pip for 5 seconds or more) 

    before proceeding

    to the next step.

Especially at short distance, the high-power beam output from 

the transmitter may reflect on objects

(walls, signboards, utility poles, etc.)

near to the protection line.

Therefore, adjust correctly 

when installing.

②Insert a test meter into the monitor jack and check the voltage. 

    Monitor output level corresponds to the distance.

Test meter

Test meter

Monitor jack

Monitor jack

③If the distance to the reflector and the converted value of the

    test meter do not match, fine adjust the optical axis of the lens unit

    or remove any objects near to the protection line.

④Press the distance setting button.

    The distance between the sensor and the

    reflector is set while pip is sounding.   

    Be careful not to block the optical unit 

   (protection line) with your body or hands.

①For the light reception level check, set the monitor output

    changeover switch to " Reception ".

②Set tone indicator setting to “ON”.  

    If the tone indicator is undesirable (at night), proceed directly to ④.

③Fine-tune the optical unit the tone becomes continuous and as 

    high-pitched as possible.

    

④ For more accurate adjustment, insert a test meter into the monitor jack 

     and check the voltage.

As a guide, the monitor voltage is shown in the above table.

However, adjust the sensitivity to as high level as possible in order

to improve environmental resistance.
The monitor voltage of the light reception level may change due

to the ambient temperature or just after turning on the power.

Distance

Reception

Monitor output

changeover switch

Utility poles, etc.

Beam reflected

on objects

Beam on 

protection line

Distance setting

button

push

By this operation, the distance between the sensor and the reflector is

memorized so that the adjustment and alarm judgment are

properly performed. So be sure to press the distance setting button.   

Before pushing this button, the pitch of tone indicator and

monitor output voltage are kept based on the previous setting.

So be sure to make adjustment after pressing the button.

※Once memorized, the setting will not be reset without pressing the

    button again, even if the power is turned on again.   When incorrect

    distance is set, go back to [

2. Distance check

] and do the setting 

    again.

Distance

Reception

Monitor output

changeover switch

Tone indicator 

Function setting switch

ON

OFF

Vertical angle

Horizontal angle

Lens unit

When the light reception level is

"Good", Sensitivity attenuation

/Environment LED turns off.

Vertical 

adjustment

screw

Light reception level

Much

Intermittent tone

(Best)

(Good)

Continuous tone

(Low)

Tone

(High)

Pip(tone : long ⇔ short) 

Bleep

LED: ON

LED: OFF

Little

Monitor output

voltage

Reception

sensitivity

More than 2.5V 

Best

2.0 to 2.5V

Good

Less than 2.0V

Re-adjustment

In case tone indicator is “ON”, walk test mode follows for 5

minutes and makes pip sound when detecting.

    

→ 

Refer to “

9. OPERATION CHECK

※Once walk test mode is completed, no pip sound is heard even with 

    the tone indicator "ON".

(Note)

If no sound comes out, the sensor unit may not face the direction of the 

reflector. In this case, go back to  [

1. Before checking

] and do the setting 

again. Also check that the tone indicator switch is ON.

When the direction of the optical axis roughly matches the reflector,

a  beep  sound  begins  which  changes  according  to  the  light  reception 

level as below.

Содержание PR-30BE

Страница 1: ...Flight technology consist of a sensor integrating both a transmitter and a receiver inside and a re ector As illustrated an infrared beam projected by the transmitter is re ected back to the receiver...

Страница 2: ...them into the following categories As these are important be sure to read and strictly observe them Installation on uneven ground Installation in locations where the device may be splashed by dirty wa...

Страница 3: ...1 7 to 100 ft INDOOR 0 5 to 40m 1 7 to 135 ft POSITION OF INSTALLATION INSTALLATION OF MULTIPLE SENSORS CAUTIONS ON INSTALLATION 80 to 100cm 31 to 39 PROTECTION DISTANCE HEIGHT OF INSTALLATION Center...

Страница 4: ...just them to each center 127mm 5 58mm 2 28 Hood xing screw Self tapping screws Note In case of outdoor installation please do not remove hood POLE MOUNTING Follow the same procedure as wall mounting f...

Страница 5: ...iable operation Make sure that angle remains within 15 even if angled installation is needed When exceeding this the amount of re ected light will be insu cient and it will not operate correctly Lens...

Страница 6: ...ossible For more accurate adjustment insert a test meter into the monitor jack and check the voltage As a guide the monitor voltage is shown in the above table However adjust the sensitivity to as hig...

Страница 7: ...mount of light re ected and returned may change so suddenly that an alarm signal is output Tone Indicator Function setting switch DIP 5 When tone indicator switch is ON reception level is noti ed with...

Страница 8: ...e ector Resin clear black REFLECTOR SENSOR Do not clean the cover with a cloth Daily check Do not clean the cover with a cloth Check the operation of the unit once a week If the cover becomes soiled w...

Отзывы: