Mounting
●
Install the unit to a beam tower.
Some towers could block the beam within its
case when the mirror is turned by
±
90
°
vertically.
Please refer to the instruction manual of the
beam tower carefully before use.
●
Beam sensor's reflecting mirror can be moved
horizontally (
±
90 degrees) and vertically
(
±
10 degrees) allowing the unit to work in all
directions.
±10°
±90°
90°
Power
(
12VDC
)
Alarm
Control panel
6) Wiring Distance between sensor and control panel.
3. Terminal arrangement
When using this product in a Mercantile Burglar
Alarm, UL681, tamper switch should be connected
to a 24 hour supervisory loop.
●
Standby battery
Be sure the control panel is equipped with
adequate standby battery and charging circuit.
Use 12V (at least) Nicd or lead acid battery
with minimum capacity of 0.5AH.
*
Max. wiring distance when two
or more sets are connected is
the above value divided by the
number of sets.
Note 1)
The signal line can be wired to
a distance of up to approx.
3300' (1000m) with AWG 22
(Dia. 0.65mm) telephone wire.
Note 2)
Unit should be connected to a listed, class 2
power source capable of providing standby
power for a minimum of 4 hours.
●
̶
Estimated battery life
̶
AWG20 (Dia.0.8mm)
AWG18 (Dia.1.0mm)
AWG17 (Dia.1.1mm)
AWG16 (Dia.1.25mm)
AWG15 (Dia.1.4mm)
AWG14 (Dia.1.6mm)
630' (192m)
1000' (300m)
1200' (366m)
1550' (473m)
1950' (595m)
2550' (777m)
4400' (1340m)
6900' (2100m)
8400' (2560m)
10500' (3200m)
13500' (4000m)
17500' (5340m)
wire size
voltage
12V DC
24V DC
No. of
pair
Md AA
0.5AH
Gel Cell
5.0AH
Gel Cell
1.0AH
1
2
4
8
5 hr
̶
̶
̶
11 hr
5 hr
̶
̶
58 hr
29 hr
14 hr
7 hr
[Transmitter]
[Receiver]
Power
10V to 30V DC
(Non-polarity)
1
2
Power
10V to 30V DC
(Non-polarity)
1
2
Alarm output Form C
30V AC/DC 1A or less
COM
NO
NC
Environmental Form C
30V AC/DC 1A or less
COM
NC
NO
3
4
5
10
8
9
③
4) 2-stacked standard connection.
5) When environmental module is used.
Note) Refer to 5. FUNCTIONS DESCRIPTION
for beam channel (beam frequency selection).
[Cautions on wiring]
●
●
TR.
RE.
TR.
RE.
Power (12VDC)
Alarm
Contorol panel
}
}
Tamper (1b)
}
Environmental signal (1C)
}
1
1
2 3 4
2
(CH.1)
(CH.3)
}
}
1
1
2 3 4
2
1
1
2 3 4
2
6 7
8 9 10
6 7
Signal output on receiver can not be used independently for the upper /
lower optics, only as a set.
Outdoor wiring should be in PVC if below ground or use direct burial
cable. Conduit should be used for above ground wiring.