background image

1) DO'S AND DON'T'S

2) Protection distance

2

CAUTIONS ON INSTALLATION

Do not install the unit on 
places where it may be 
splashed by dirty water or 
direct ocean spray.

Do not install the unit on 
unsteady surfaces. 

Do not install the unit at places 
where it may be interrupted by 
obstacles such as trees. 

Avoid strong light from the 
sun, automobile headlights 
etc. shining on transmitter 
and receiver directly. (Avoid 
light within 

±

2

°

degrees of  

optical axis.)

1

Basic connection

The equipment must be powered from an LPS in accordance with EN60950-1 : 2001

2

When two or more sensors are 

    connected to the same line.

3

When two or more sensors are 

    connected to separate lines.

Power

DC12V

Power

DC12V

Power

DC12V

Alarm signal

N.C.

Alarm signal

N.C.

1

Alarm signal

N.C.

2

Alarm signal

N.C.

Control panel

Control panel

Control panel


1

1

2 3 4

2

Wiring


1

1

2

1 2

3 4

1 2

3 4

2



1

1

2

1 2

3 4

1 2

3 4

2

TR

RE

TR

RE

TR

RE

TR

RE

TR

RE

Max protection distance 

330' (100m)

8' (2.4m)

View finder

TR

RE

1

PARTS DESCRIPTION

Mirror

Horizontal angle 

adjuster

Vertical angle 

adjuster

Terminals

Gain lock switch

Receiver only

Indication panel

Mirror

TR : Shading plate
RE : Shading plate +

sensitivity checker

Adjustment dial

[Transmitter]

[Receiver]

Operation LED

Beam power
(H set at factory)

Beam channel frequency
selectable switch
(frequency 1-4)
(1CH. set at factory)

Sensitivity attenuation 
LED

Beam channel
(frequency 1-4)
(1CH. set at factory)

Beam selector
(upper set at factory)

Response time 
adjustment

OR

(0.1sec. set at factory)

Environmental output 
terminal

Alarm LED

Beep (Alignment tone) 
switch
(OFF set at factory)

Response time 
adjustment

AND

(0.035sec. set at factory)

Monitor jack

Functions / Indcations

Panhead screw

    (M

3

×

12

8

Lock spacer

  

1

Accessories

Содержание PB-100AT-KH

Страница 1: ......

Страница 2: ... C 2 Alarm signal N C Control panel Control panel Control panel 1 1 2 3 4 2 Wiring 1 1 2 1 2 3 4 1 2 3 4 2 1 1 2 1 2 3 4 1 2 3 4 2 TR RE TR RE TR RE TR RE TR RE Max protection distance 330 100m 8 2 4m View finder TR RE 1 PARTS DESCRIPTION Mirror Horizontal angle adjuster Vertical angle adjuster Terminals Gain lock switch Receiver only Indication panel Mirror TR Shading plate RE Shading plate sensit...

Страница 3: ...nected to a listed class 2 power source capable of providing standby power for a minimum of 4 hours Estimated battery life AWG20 Dia 0 8mm AWG18 Dia 1 0mm AWG17 Dia 1 1mm AWG16 Dia 1 25mm AWG15 Dia 1 4mm AWG14 Dia 1 6mm 630 192m 1000 300m 1200 366m 1550 473m 1950 595m 2550 777m 4400 1340m 6900 2100m 8400 2560m 10500 3200m 13500 4000m 17500 5340m wire size voltage 12V DC 24V DC No of pair Md AA 0 5...

Страница 4: ......

Страница 5: ...e appropriate beam intensity relative to the application For distance significantly less than the specified protection distance the beam intensity should be reduced to eliminate potential reflection problems For zones reaching maximum protection distance the beam level should be set to the highest level Note The use of a voltmeter for alignment is advised to ensure highest level of stability Consu...

Страница 6: ...of the beam that is selected by the beam selector is indicated on sensitivity attenuation LED Sound check tone and monitor output When a lock spacer is inserted this function is canceled and sensitivity attenuation LED lights regardless of positioning of the selector even when either side of beam is attenuated Tone Indicates Result Cause Remedy Optimal sensitivity has been set One pulse Beep OK Co...

Страница 7: ...age 3 Remove the shading object 4 Change the place for installation 5 Stabilize 6 Clean the optics with soft cloth 7 Check and re adjust 8 Change environments or the place for installation 9 Set beam power switch at H and make the unit gain locked with receiver cover detached Intermittent alarm Units should be tested on a regular weekly basis Model Detection system Infrared beam Protection distanc...

Страница 8: ...uraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING Changes or modifications not express...

Отзывы: