Takex PA-480S Скачать руководство пользователя страница 2

Caution

Passive infrared sensors are designed to detect changes of 
far-infrared ray energy. Energy changes largely when the human 
body moves across the detection area. However, energy does not 
change so much when the human body 
comes closer in a straight line, or stops.
In addition, if the environment of detection 
area generates similar changes due to certain 
factors, the unit will issue an alarm without 
being able to judge properly.

Avoid installing the unit in the following places. 
Otherwise, non-detection and/or false detection may occur.
• Places subject to strong direct or reflected light (sunlight, spotlight)
• Places subject to rapid temperature fluctuations (air outlets of 

air-conditioning equipment, etc.)

• Places where moving objects are included in the protection area 

(plants, laundry, etc.)

• Places subject to strong vibration and/or electric noise
• Places where pets, such as dogs and cats, and/or automatic 

cleaning robots may pass

• Places where shielding objects (including glass and transparent 

resin, etc.) are placed in the protection area (shading parts will not 
be detected)

• Places that people can easily touch.

Securely conduct installation work according to the instruction 
manual.
Also, make sure to use the supplied accessories and specified 
components.
Failure to follow this may result in injury and/or property damage in 
the event of fire, electric shock or fall of the unit.

Ask qualified personnel for any electrical work necessary for 
installation, if required.
Failure to follow this may result in fire and/or electric shock.

This unit is for indoor use. Do not use the unit in places subject  to 
water and/or high humidity. Failure to follow this may result in 
malfunction if water gets into the unit.

This unit is not a waterproof (moisture proof/rainproof) or dust-proof 
structure. Do not use the unit in places subject to water and/or high 
humidity, such as bathrooms, and/or subject to large amounts of 
dust or sand. Failure to follow this could result in malfunction.

Do not perform aerial wiring of power and signal cables. Failure to 
follow this may result in electric shock, fire, and/or malfunction.

3

DETECTION AREA

NORMAL
(FACTORY SETTING POSITION)

Plants/Curtain

Refrigerator

Shielding objects

Facing the window

Do not install the sensor directly on the ceiling 
(When installed on ceilling, use optional 
attachment BCW-401)

AREA ADJUSTMENT

AREA LOCK

ADJUSTMENT DIAGRAMS

Different coverage by 90°each

WALL MOUNT
APPLICATION

170°

85

°

35°

18°

11°

52.5

(16m)

26.3

(8m)

(8.2

) 2.5

2.0

1.0

0

(m)

(8.2

) 2.5

2.0

1.0

0

(m)

(8.2

) 2.5

2.0

1.0

0

(m)

(8.2

) 2.5

2.0

1.0

0

(m)

(8.2

) 2.5

2.0

1.0

0

(m)

(26.2

)

0      1      2      3      4      5      6      7      8(m)

(26.2

)

0      1      2      3      4      5      6      7      8(m)

(26.2

)

0      1      2      3      4      5      6      7      8(m)

(26.2

)

0      1      2      3      4      5      6      7      8(m)

(26.2

)

0      1      2      3      4      5      6      7      8(m)

8.2

(2.5m)

PILLAR MOUNT
APPLICATION
(2 units)

The area of protection is adjusted to allow  for different mounting hights. 
By moving the inner unit upwards, the coverage of the sensor is 
decreased.

After adjustment, lock the inner unit 
with the provided area lock screw.

The area can be adjusted 
independently 90°each side to side 

Hole the inner unit to move.

Check operation whenever the 
protected area is changed.