5-28
MAINTENANCE
INSPECTING THE BATTERY FLUID LEVEL
AND REPLENISHING
DANGER
• Do not use the battery when the fluid
level is below the lower level limit. Doing
so will hasten the deterioration of the
internal portions of the battery and
shorten the battery life. It also can
cause rupturing (explosion).
• Batteries generate flammable hydrogen
gas which may explode. Keep away
from flame, sparks, fire or lighted
cigarettes.
• Use a dampened cloth to clean above
the fluid level line and check the fluid
level. Do not clean with a dry cloth;
otherwise it can cause static electricity
to build up, resulting in ignition or
explosion.
WARNING
• Wear protective goggle and clothing
when working with batteries.
• Do not add the distilled water above the
upper level limit. Doing so could cause
the fluid to leak. This fluid can cause
skin damage if contacted, or can cause
the machine components to corrode.
• Batteries contain sulfuric acid which will
damage eyes or skin if contacted.
· If eye contact occurs, flush
immediately with clean water and get
prompt medical attention.
· If accidentally swallowed, drink large
quantities of water or milk and call a
physician immediately.
· If acid contacts skin or clothing, wash
off immediately with a lot of water.
• Be sure to secure the rear door or
radiator before working the inside.
Inspection
IMPORTANT: Check the fluid level of all
cells following the steps below, even
when the fluid level can be checked using
the indicator.
Note:
Under normal operating conditions,
the maintenance-free battery does not
require addition of water because of the
special plate designed to minimize fluid loss.
However, for those machines that are heavily
used or operated under severe conditions
(for example, in high ambient temperature),
the fluid level often becomes low. If that is
the case, check the fluid level of the
maintenance-free battery and add water as
needed.
1. Open the rear door.
2. Inspect the indicator (1).
· Blue: Charging complete
· White: OK
· Red/center White: Insufficient battery
fluid
· Red/center Red: Charging needed
3. Inspect the fluid level.
The fluid level must be between the upper
level line (H) and lower level line (L). If not,
add distilled water up to the line (H).
EVERY 50 HOURS
Содержание TL230
Страница 1: ......
Страница 10: ...0 8...
Страница 11: ...1 1 SAFETY...
Страница 47: ...1 37 SAFETY SAFETY SIGNS DECALS...
Страница 48: ...1 38 SAFETY SAFETY SIGNS DECALS...
Страница 49: ...1 39 SAFETY SAFETY SIGNS DECALS...
Страница 50: ...1 40 SAFETY SAFETY SIGNS DECALS...
Страница 51: ...2 1 CONTROLS...
Страница 89: ...3 1 OPERATION...
Страница 95: ...3 7 MEMO...
Страница 116: ...3 28...
Страница 117: ...4 1 TRANSPORT...
Страница 121: ...5 1 MAINTENANCE...
Страница 174: ...5 54...
Страница 175: ...6 1 TROUBLESHOOTING...
Страница 190: ...6 16...
Страница 191: ...7 1 SPECIFICATIONS...
Страница 193: ...7 3 MEMO...
Страница 194: ...7 4 SPECIFICATIONS MACHINE DIMENSIONS MACHINE DIMENSIONS...
Страница 196: ...7 6 SPECIFICATIONS OPERATING RANGES OPERATING RANGES...
Страница 198: ...7 8...
Страница 199: ...8 1 OPTIONS...