175
OPTIONS
Hydraulic Breaker
Replace the hydraulic oil
regularly!
¡
When using a hydraulic breaker, the oil
deteriorates quicker than during normal
digging. Be sure to replace the hydraulic
oil and return filter element.
• Failure to replace these in time can lead
to damage to the machine and breaker’s
hydraulic systems. In order to improve
the service life of the hydraulic systems,
be sure to replace the hydraulic oil and
return filter element according to the
following chart of the replacement
interval.
• Clean the suction strainer when
changing the return filter element.
Replacement Interval (Hours)
Item
Hydraulic Oil
Return filter
1st time
25
2nd time
100
Periodically
600
200
when the breaker operating ratio is 100%
2000
1500
1000
500
0
40
100
80
60
20
Breaker operating ratio (%)
Replacement inter
v
al (H)
N0G036
Replacement interval
for hydraulic oil
Replacement
interval for filter element
¡
Do not drop the breaker itself on the object
to be broken in order to break it.
¡
Do not move objects to be broken or rocks
with the breaker itself.
¡
Slew occasionally to cool the engine.
¡
If a hydraulic hose is vibrating abnormally,
nitrogen gas may be leaking from the
accumulator. Have an inspection as soon
as possible.
Содержание TB53FR
Страница 6: ...4...
Страница 8: ...6...
Страница 91: ...89 TRANSPORT Loading and Unloading 90 Securing the Machine 91 Cautions on Transporting 92...
Страница 140: ...138...
Страница 152: ...150...
Страница 153: ...151 SPECIFICATIONS Main Specifications 152 Machine Dimensions 154 Operating Range 156 Lifting Capacities 159...
Страница 156: ...154 SPECIFICATIONS Machine Dimensions J1K0011 N L M D Q P J H K C F G A S E B R T U...
Страница 158: ...156 SPECIFICATIONS Operating Range J1K0021 D J H K C F G A E B...
Страница 160: ...158 MEMO...
Страница 168: ...166...
Страница 174: ...172 MEMO...
Страница 186: ...184...
Страница 187: ...185 INDEX...