Page 5 of 15
Product Carriage Setup
1.
Keeping the product carriage table (34) level, raise or lower the product carriage by
loosening the ratchet handles (2). With the Air System Disconnected raise the carriage to
make contact with the Product Drive Roller (30).
2.
Position the product rollers (44) with the center of the bottle under the Product Drive
Roller (30).
3.
Then manully raise the head 1/8” and raise the carriage again until it makes contact with
the Product Drive Roller (30). Connect the Air system at this time.
4.
The product should be setting on the product rollers (44) so it will roll easily. If the label
tends to “walk” to one side of the bottle during application, the product rollers (44) may
need to be repositioned. Some products may even require one of the product rollers (44)
to be slightly skewed.