[Pipe specifications]
Ensure that the material or finishing of the floor surface is waterproof or has a waterproof coating applied.
Always ensure that the floor surface is horizontally level.
Ensure that the floor surface is smooth and free from bumps around the attachment areas.
Installing pipes
The following levels of strength are required for the floor surface.
Floor surface
For installation on the wall, the wall base strength should be equal to or stronger than a 12mm-thick
composite panel. If the wall is made of plaster or its thickness is less than 12mm, add a wooden
reinforcement onto the wall(See page 2).
Use a waterproof material such as melamine for the wall surface (for possible water splashes during
shampoo treatment).
Wall
In case of the installation on the first floor of higher,waterproof the floor appropriately
(e.g. do water proofing work, use a floor tray made of stainless steel, set up a water leak sensor, etc.)
Waterproofing
Drainage
Rc 1 / 2“ pipe from floor Hotwater supply H : 110mm
water supply H : 80mm
VU40 Pipe from floor H : 170mm
Hot water supply, water supply
Wooden floor
Mortar floor
Mortar thickness of 50 mm or more
Special floor (stone finish)
A foundation with levels of strength listed above around the installation areas is required.
Plywood thickness of 30 mm or more (two 15 mm sheets joined together)
Installation of pipes
The following are important points to adhere to during the installation of pipes.
Read through the details carefully and ensure that the pipes are installed correctly.
When installing this product, ensure that installation of pipes adheres to the instructions outlined in "Precautions
during installation of pipes". Installing pipes without reading through the precautions will mean water may not mix
properly, and a set temperature will not be achieved.
This product is designed for indoor installation. Always install this product indoors.