Installation of Main unit

5

●Opening of the packing

(1) Takes out the base.

●Secure the fixing base on the floor using the screws or the anchor bolts.

Fix the base to the floor with four screws and washers.

a) Plywood floor

b) Concrete floor

c) Tile floor

; Hex head tapping screw M8-60

; Anchor bolt M8-70

; Remove the tile with template paper.

  Put the plywood and fix the shampoo unit to the floor.

●Marking the bolt anchor points

○Refer to the floor template (pages 14 to 15) and overall layout diagram, check the dimension of the 

raised pipes of water, hot water and drain, and prepare for the installation.

(1) Set the paper template on the floor aligning it with the floor fixing position of the fixing base.

*The floor fixing point of the fixing base differs depending on the chair used with Yume Swing.

(2) Mark the screw or bolt anchor position of the fixing base (four locations).

15mm within

Caution

To use a fixed position adjacent if you can not use the standard fixed position.

To increase the fixed position when the strength of the floor can not be taken well.

Since the cover and base of the interval is narrow, the floor finish up when the base.

The depth of the pilot hole of the anchor bolt, the bolt head is set to be from the floor 

within 15mm.

Screw

Washer

Base

Содержание RS

Страница 1: ...install RS SWING Customers must not install RS SWING by themselves Customers must store these instructions in a safe place so as not to lose them To the installer The instructions should be thoroughly...

Страница 2: ...pipes The following are important points to adhere during the installation of pipes Read through the details carefully and ensure that the pipes are installed correctly This product is designed for i...

Страница 3: ...he hot water temperature to 80 or less Set the temperature 10 or highter than the shower temperature used Water used Hot water supply water supply pressure Hot water temperature into the product Water...

Страница 4: ...e Base cover Plug Drain cap Hair catcher Basin Main unit Stainless flexible pipe Stop valve Stop valve knob Rear cover Neck cushion Front cover Level adjustment plate Screw Set Operationg manual Insta...

Страница 5: ...es of water hot water and drain and prepare for the installation 1 Set the paper template on the floor aligning it with the floor fixing position of the fixing base The floor fixing point of the fixin...

Страница 6: ...five fixing screws spring washers and flat washers Bolt to be used M8 hexagonal head bolt with washer 5pcs 6 Caution Always have at least two peole to do this process it may cause breakage of the prod...

Страница 7: ...Fixing Screws Adjuster Screw Adjuster Screw 4 locations Fixing Screw 5 locations 2 Fasten the Fixing Screw Height and horizontal adjustment 1 Using the level vial adjust the level with four adjuster s...

Страница 8: ...embling 8 Base Cover Truss Head Screw Plug Set of base cover Attach the base cover on the base Set of shampoo basin Attach the shampoo basin to the top of the arm and fix it with a truss screw and a p...

Страница 9: ...Drain Hose Bearing Sleeve VU50 Drain pipe Water Supply Hose Drain Hose Connection of the Water supply hose Connect the water supply hose and drain hose Connection of the Drain hose Insert the drain ho...

Страница 10: ...1 Fix the front cover to the shampoo unit body with six tapping screws 2 Attach the stop valve knob Before connecting the pipes remove any waste from pipes such as dust dirt sand or oil 1 Bend each st...

Страница 11: ...filtered check valve then adjust the pressure It is recommended that water supply pressure and hot water supply pressure become the same pressure Caution Always test the water flow to prevent accident...

Страница 12: ...hampoo basin mounting surface height 977 497 428 650 90 887 162 60 50 52 470 325 187 241 90 80 84 205 522 Water supply Hot water supply Drainage Drainage Water supply Hot water supply Chair side Rotat...

Страница 13: ...o prevent accidents during operation Be careful about the installation direction If the cushion is installed in the wrong direction it may contact the backseat Caution Execute the installation using t...

Страница 14: ...90 185 Raising pipe area 55 80 Water Supply 1 2 13m m Rise 60mm Hot Water Supply 1 2 15m m Rise 60mm Drainage VU40 Rise 50mm Chair Side Distance to the wall or the furniture Min 1350mm Including work...

Страница 15: ...obvious 2 Place composite panels in the peeled off area The panel surface should be higher than the surrounding tile or glass surface within 2 or 3 mm 3 Caulk gaps between the composite panels and the...

Страница 16: ...16 1E0512A0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680 NOTE...