background image

* The black caps are provided for covering the screw heads.

Follow to the instructions shown in the "How to adjust faulty temperature 

regulation (Page 10)" shown in the "RSIII Installation Instructions".
* When attaching the reducing valve, make sure that the position 
   of filter should be higher than original position. The plumbing cover 
   prevents stop valve from opening and closing smoothly.

* To attach reducing valve smoothly, remove the front cover to 

  detach the flexible pipe between thermostat and filter.

* Be sure to do this process. Failure to follow this instruction may cause water leakage inside of the plumbing cover leading to corrosion of the 
  plumbing cover and floor.

* The screw holes of the plumbing cover C are oval holes to allow minor adjustment 
   of the fixing position.
* The screw holes of the floor fixing brackets are made larger than the fixing screws 
   to allow minor adjustment of the fixing position.

(11) 

Install the maintenance cover (cut) referring to “4. Attach cover (2. Mounting the Maintenance Cover (Page 16))” of

        the “RS III  Installation Instructions”.

     

 Then, continue the installation after the process “After installation (Page 24, 25)”

.

(8) 

Place the plumbing cover C over the floor fixing bracket, and check the below points.

 1. Check and make sure that there is no large clarance at the jointed parts of the plumbing cover C.

     2. Check and make sure that the plumbing cover C could be fixed correctly to the floor fixing bracket with screws.

(9) 

After checking the installation work, fix the plumbing cover C with screws.

     

SFVRI0[VFUHZVDQGSFVRIZDVKHUijSHURQHIORRUIL[LQJEUDFNHW

   

 After screwing is finished, cover the screw head with the black caps provided with the screws.

(10) 

Apply caulking materials to any gaps between the plumbing cover C and floor.

1E01K4A0

7.2

 

Hole 

Depth 

30

(1) Drill open a hole of the 

     specified diameter and 

     depth.

(2) Remove the dust from each 

     anchor hole by cleaning with 

     a vacuum cleaner.

ĺ

 

(4) 

Attach the floor fixing bracket

     and fasten the tapping screw

     using a screwdriver.

(3) 

Insert the anchor bolt lightly 

     in the hole.

Installing screws (In the case of fixing the floor fixing bracket to mortar floor.)

Floor fixing bracket

 

Floor

     If in case the plumbing cover C can not be fixed correctly, check and correct the “Attachment position of the floor 
     fixing bracket”.

Reducing valve

(Sold separately

Filtered check

valve

Front 

cover

Stop valve

How to adjust faulty temperature regulation