background image

Practice in Standing Postur

e

Practice in Sitting Posture

Distance from the end of the  base to the wall surface or  furniture:

Practice in Standing Postur

e

Practice in Sitting Posture

COMFOR

T/AXIS/LITE

660㎜ 

or over

PRIMO

700㎜ 

or over

including an aisle of 500 mm  

(from handrail to wall surface)

201

256

40

45

45

185

272

136

243

191

36

8

400

251

149

Drainage Center

Product Center

Procedures for Installing the Pipe Gasket

RS1

NRS

W

ater Supply 

1/2”13m/m

Hot W

ater Supply 

1/2”13m/m

Drainage

VU40/VP40

110㎜

110㎜

80㎜

90㎜

90㎜

90㎜

Rise Dimen

sions of Pipe

  

Use waterproof flooring materials.

  

If the floor has an opening, cover the opening when completing the interior finishing (waterproofing).

  

Install all pipe gaskets.

180

100

37.5

Drainage

  

VU40

VP40

Rise: 100

Hot W

ater Supply

1/2” 13m/m 

Rise: 60

W

ater Supply

1/2” 13m/m 

Rise: 60

- W

ooden floor:   V

eneer board with 30 mm thickness or more

- Mortar floor:   Mortar thickness of 50 mm or more - Special floor (stone, etc.):  

The base for which the

  above-stated strength is ensured should be formed in the   installation area.

 Show the floor installation surface.

2~5㎜

Pipe Gasket (Sponge Side)

   

 

Make a cut.

 

Install the pipe 

    gasket.

Be sure to caulk 

    the pipe.

An aisle

(500

or over

The wall surface or furniture

the wall surface or furniture

Unit fixing position and Plumbing Layout

26

(1) Set the dedicated paper template on the floor by aligning it with the       rise points for the water

, hot water

, and drainage pipes.

(2) Mark the bolt anchor position of the basin main unit. (3) Drill holes at the bolt anchor position of the basin main unit. (4) Remove the paper template.

A flexible pipe of L

 = 200 mm is supplied with the product. 

The work to change the pipe from RS1/NRS is possible  without changing the rise point for the pipes.

Changing the pipe form RS1/NRS

When changing the pipe from NRS, the height of the riser drainage pipe must be adjusted to 1

10 mm.

Floor Surface of 

Tile or Glass Finish

The tiles or glass of the floor surface will break when  the bolts are embedded during installation of the  shampoo unit. If this is the case, the installation area  should be finished with materials such as plywood or  mortar

.

(1) Peel of

f the inner tiles or glass along the outside

      lines of the installation area of the floor

. The work 

     must be done carefully; otherwise, the peeled       portion may be obvious. (2) Place composite panels in the peeled-of

f area. 

     

The panel surface should be higher than the 

     surrounding tile or glass surface (within 2 or 3 mm).

Request measures to prevent water leakage under the floor and downstairs

Be sure to take the necessary precautions to prepare for and prevent possible water leaks.

(1) Make a cut in the pipe gasket at the pipe riser point.

(2) Peel of

f the adhesive sheet on the pipe gasket and set the gasket on the floor

.

(3) Cut the gasket in a circle at the cut portion on the gasket along with the pipe, and then caulk the area around the pipe.

Back End of Basin

Exterior Line of Cover

Bolt 

Anchor Point

Bolt 

Anchor Point

Bolt 

Anchor Point

Chair Side

The floor surface requires the following strength:

Distance from the end of the base side 

(aisle side) to the wall surface or furniture:

Bolt 

Anchor Point

Bolt 

Anchor Point

End of Base Side

Area of Floor Cutout 100 x 180

Caution for 

Anchor Bolt Installation

Anchor bolts should be installed so that the  screws will protrude from the bolt head by 3 to  5 mm. If the protrusion exceeds 5 mm, the bolt  head may interfere with the cover

.

Exterior Line of Cover

Distance from the end of the  basin to the wall surface or  furniture : 

600㎜ 

or over

630㎜ 

or over

Base End Position

Basin Side

859㎜ 

or over

889㎜ 

or over

Bolt 

Anchor Point

Avoid the anchor positions when installing  the pipe risers.

Caution

[ Unit : mm]

Содержание RS III PRIME

Страница 1: ...instructions may be modified and are subject to change without notice Caution The precautions listed here are to ensure that RS can be installed safely and to prevent any danger or risk to the person...

Страница 2: ...siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt sand and oil as these can cause problems After connec...

Страница 3: ...t use non drinkable well water or water that contains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may...

Страница 4: ...g Sheet Pipe packing Chair Main Unit Chair Fixing Screws M8 x 70 Hexagonal head bolt with plain washer spring washer 4 pcs Chair Main Unit Chair Main Unit Chair Side Chair Side The illustration shows...

Страница 5: ...an head machine screw 2 pcs The illustration shows SU COL Double Step Step Fixing Screws M8 x 30 hexagonal head bolt with spring washer 4 pcs U shaped Step Step OR Chair Main Unit The illustration sho...

Страница 6: ...sin Take extra care to ensure not to damage the covers Do not touch the basin body pipes Doing so may cause water leaks The basin is unstable when it is not fixed to the floor Carrying in the Shampoo...

Страница 7: ...Supply Pipe Water Supply Pipe Drainage Pipe RS3 Paper Template Paper Template Request measures to prevent water leakage under the floor and downstairs Be sure to take the necessary precautions to pre...

Страница 8: ...1 Set the lower chair cover so that the claw of the cover will hang on the tentatively fixed truss head screw M5 x 12 8 Claw 3 Fully tighten the truss head screws two locations Truss head tapping scre...

Страница 9: ...hen changing the pipe from NRS the height rise of the drainage pipe must be adjusted Detach the joint connected to the drainage pipe and make the adjustment so that the height rise of the drainage pip...

Страница 10: ...and clean any dirt trapped within the shower head Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not i...

Страница 11: ...p Mounting Washer 2 Brass Hex Nuts 2 Pipe Nipples 2 Mounting Bar Fastening Bolt and Wing Nut Front 1 Preassembled Vacuum Breaker Vacuum Breaker Rubber Gasket Hose Receiver Cap and pipe nipples with th...

Страница 12: ...G 1 4 L800 CONNECT TO THE HOT WATER PIPE AND WATER PIPE INCLUDED VACCUME BREAKER TABLE HOLE PLUG VACCUME BREAKER TABLE CUT THE PLUG AND RUN THE PIPES INTO THE COVER Water supply pipe Hot water supply...

Страница 13: ...n included with the hair trap Attach the drain hose using a hose clamp and apply silicon sealant as require around fitting for a water seal Check carefully for any leaks prior to putting the until int...

Страница 14: ...o unit by aligning the center of the mounting pipes four pieces at the back of the chair and the center of the slotted hole of the chair mounting fixture of the shampoo unit 2 Check that the centers o...

Страница 15: ...iron plate with pan head machine screws M6 x 15 two locations C 5 Tighten the screws for the square pipes which loosened first four locations A 1 Mount the backrest with pan head machine screws three...

Страница 16: ...he latch on the upper side and then hook the two latches on the lower side 2 Mounting of the Chair to the Shampoo Unit 1 Mounting the Armrest Pad Mount the armrest pad with truss head screws four loca...

Страница 17: ...122 111 124 3 6 5 1 4 0 2 2 409 6 Center of Drainage Pipe Rise Dimension Hot water supply 60 mm Water supply 60 mm Drainage 100 mm Basin Operation Angle for Basin Tilt Specification 0 340 462 565 49...

Страница 18: ...cation 353 1193 Seat Slide Width 150 mm Max 6 109 122 111 124 410 3 6 5 1 4 0 2 2 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 Note The dimensions in parentheses show t...

Страница 19: ...109 122 111 124 3 6 5 1 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 567 495 574 446 175 474 49 565 555 176 173 132 129 Note The dimensions in parentheses show the dim...

Страница 20: ...ushion 706 135 138 2 140 1 1625 Double step Specification 1483 U step Specification 259 468 8 8 4 1 4 5 1 5 359 Center of Drainage Pipe Basin Operation Angle 0 340 590 49 175 525 565 555 173 176 129 1...

Страница 21: ...uding neck cushion 659 259 468 1 2 8 4 6 5 382 130 430 Center of Drainage Pipe 0 592 49 175 523 565 554 173 176 129 132 The drawing shows AY S195X AY P069X Basin Operation Angle Height of armrest lead...

Страница 22: ...g neck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY LUXIS AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dim...

Страница 23: ...eck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY ELI AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dimensio...

Страница 24: ...ration Be careful about the installation direction If the cushion is installed in the wrong direction it may contact the backseat Caution Seat side Basin side Execute the installation using the follow...

Страница 25: ...lumber cover and put it on the lumber 3 Place the lumbar cover with the cutout side facing down and align the cover and the corner of the lumbar component Fit the cover over the lumbar part in the se...

Страница 26: ...he pipe form RS1 NRS When changing the pipe from NRS the height of the riser drainage pipe must be adjusted to 110 mm Floor Surface of Tile or Glass Finish The tiles or glass of the floor surface will...

Страница 27: ...27...

Страница 28: ...28 1E02VYA0 NOTE 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Отзывы: