11
<AY-P073X,AY-074X>
1. Attach the vacuum breaker
Faucet
Water Outlet
Hot Line(Red)
Cold Line(Blue)
Spray Hose
Brass Hex Nut
Rubber Gasket
Metal Washer
1) Insert #550 Faucet with Rubber Gasket into Bowl
as shown.
2) Place Metal Washer over threaded body of Faucet
and tighten securely with Brass Hex Nut.
Make sure the pointed
tip on handle is pointed to
rear of the bowl.
Note : Secure the flexible hose of Faucet
prior to mounting bowl
Note : Flushing hot and cold lines before attaching
Faucet recommended
Note : Apply clear silicone sealant as required
around fittings for a water tight seal.
Note : Use pipe sealing tape on threads
2. Attach the faucet
Vacuum Breaker
Vacuum Breaker
Rubber Gasket
Hose
Receiver Cap
Rubber Gasket for
Hose Receiver
Cap Mounting
Washer (2)
Brass
Hex Nuts (2)
Pipe Nipples (2)
Mounting Bar
Fastening Bolt
and Wing Nut
Front
1) Preassembled Vacuum Breaker, Vacuum Breaker
Rubber Gasket, Hose Receiver Cap and pipe
nipples with the short pipe installed in line with
the arrow that points down on the vacuum breaker
body.
Note : Use pipe sealing tape on threads at both ends
of the nipples
2) Attach the assembly with Hose Receiver Rubber
Gasket to the bowl and place the Fastening Bolt
and Wing Nut through the Mounting Bar.
Align and tighten securely by hand only.
Do not over tighten.
3) Attach connecting hose (G 1/4 L800) to the long
pipe nipple. (arrow pointing up)
Insert spray hose through opening in hose reveiver cap and
attach to the outlet on the vacuum breaker (short pipe nipple, arrow pointing down).
Connect G 1/4 L800 connecting hose to the inlet on the vacuum breaker (long pipe
nipple, arrow poinging up) and the other end of outlet on the faucet.
3. Connect the hoses