background image

Contents

Before installation
Usage conditions
Content of packaging
Carrying the main body

Dimensions
After installation
Unit fixing position and Plumbing Layout

MEMO




17
24
26
27

1.Installation of Shampoo Unit
2.Piping
3.Attach the seat

     <AXIS

PRIMO

LITE

PRIME

LUXIS>

     <COMFORT>

     <ELITE>

4.Attach cover


14

14

15

16

16

1

RS

 Installation Instructions

To the installer

• The instructions should be thoroughly read 

and understood before installation to ensure 

that RS

 is installed correctly.

After installation, give these instructions to the customer.

• 

To the customers

• Customers must ask proffessional to install RS

.

• Customers must not install RS

 by themselves.

• Customers must store these instructions in 

   a safe place so as not to lose them.
* The actual shape of RS

 and the images and 

  dimensions listed in these instructions may be modified

  and are subject to change without notice.

Caution

 The precautions listed here are to ensure that RS

can be installed safely, and to prevent any 

danger or risk to the person installing RS

or those around them. All of these precautions are 

important for safety. Takara Belmont is not responsible 

for any damage or risk to the person installing RS

or those around them due to accidents if 

RS

 is installed without adhering to the precautions.

If RS

 is installed after ignoring this symbol, 

"there is the risk of light or moderate injury or physical 

damage".

Version 4 Feb 2016

PRIME

Image is of  

    

AY

-

S195X

    

AY

-

P069X

AXIS

PRIMO

COMFORT

LITE

ELITE

Image is of

    

AY

-

ELI

    

AY

-

P075X

(

)

(

)

LUXIS

Image is of  

    

AY

-

LUX

    

AY

-

P069X

(

)

Note : Plumbing should be performed by a qualified 

technician and should meet all national and local 

plumbing codes and ordinances. It is the responsibility 

of purchaser and/or plumber to conform to national 

and local codes and ordinances.  Takara Belmont does 

not take any responsibility or liability for plumbing and

installation.

Содержание RS III PRIME

Страница 1: ...instructions may be modified and are subject to change without notice Caution The precautions listed here are to ensure that RS can be installed safely and to prevent any danger or risk to the person...

Страница 2: ...siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt sand and oil as these can cause problems After connec...

Страница 3: ...t use non drinkable well water or water that contains rust or sand If the water hardness is 80 ppm or higher install a water softener to prevent the buildup of scale within the basin body Aeration may...

Страница 4: ...g Sheet Pipe packing Chair Main Unit Chair Fixing Screws M8 x 70 Hexagonal head bolt with plain washer spring washer 4 pcs Chair Main Unit Chair Main Unit Chair Side Chair Side The illustration shows...

Страница 5: ...an head machine screw 2 pcs The illustration shows SU COL Double Step Step Fixing Screws M8 x 30 hexagonal head bolt with spring washer 4 pcs U shaped Step Step OR Chair Main Unit The illustration sho...

Страница 6: ...sin Take extra care to ensure not to damage the covers Do not touch the basin body pipes Doing so may cause water leaks The basin is unstable when it is not fixed to the floor Carrying in the Shampoo...

Страница 7: ...Supply Pipe Water Supply Pipe Drainage Pipe RS3 Paper Template Paper Template Request measures to prevent water leakage under the floor and downstairs Be sure to take the necessary precautions to pre...

Страница 8: ...1 Set the lower chair cover so that the claw of the cover will hang on the tentatively fixed truss head screw M5 x 12 8 Claw 3 Fully tighten the truss head screws two locations Truss head tapping scre...

Страница 9: ...hen changing the pipe from NRS the height rise of the drainage pipe must be adjusted Detach the joint connected to the drainage pipe and make the adjustment so that the height rise of the drainage pip...

Страница 10: ...and clean any dirt trapped within the shower head Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not i...

Страница 11: ...p Mounting Washer 2 Brass Hex Nuts 2 Pipe Nipples 2 Mounting Bar Fastening Bolt and Wing Nut Front 1 Preassembled Vacuum Breaker Vacuum Breaker Rubber Gasket Hose Receiver Cap and pipe nipples with th...

Страница 12: ...G 1 4 L800 CONNECT TO THE HOT WATER PIPE AND WATER PIPE INCLUDED VACCUME BREAKER TABLE HOLE PLUG VACCUME BREAKER TABLE CUT THE PLUG AND RUN THE PIPES INTO THE COVER Water supply pipe Hot water supply...

Страница 13: ...n included with the hair trap Attach the drain hose using a hose clamp and apply silicon sealant as require around fitting for a water seal Check carefully for any leaks prior to putting the until int...

Страница 14: ...o unit by aligning the center of the mounting pipes four pieces at the back of the chair and the center of the slotted hole of the chair mounting fixture of the shampoo unit 2 Check that the centers o...

Страница 15: ...iron plate with pan head machine screws M6 x 15 two locations C 5 Tighten the screws for the square pipes which loosened first four locations A 1 Mount the backrest with pan head machine screws three...

Страница 16: ...he latch on the upper side and then hook the two latches on the lower side 2 Mounting of the Chair to the Shampoo Unit 1 Mounting the Armrest Pad Mount the armrest pad with truss head screws four loca...

Страница 17: ...122 111 124 3 6 5 1 4 0 2 2 409 6 Center of Drainage Pipe Rise Dimension Hot water supply 60 mm Water supply 60 mm Drainage 100 mm Basin Operation Angle for Basin Tilt Specification 0 340 462 565 49...

Страница 18: ...cation 353 1193 Seat Slide Width 150 mm Max 6 109 122 111 124 410 3 6 5 1 4 0 2 2 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 Note The dimensions in parentheses show t...

Страница 19: ...109 122 111 124 3 6 5 1 Center of Drainage Pipe Basin Operation Angle for Basin Tilt Specification 0 567 495 574 446 175 474 49 565 555 176 173 132 129 Note The dimensions in parentheses show the dim...

Страница 20: ...ushion 706 135 138 2 140 1 1625 Double step Specification 1483 U step Specification 259 468 8 8 4 1 4 5 1 5 359 Center of Drainage Pipe Basin Operation Angle 0 340 590 49 175 525 565 555 173 176 129 1...

Страница 21: ...uding neck cushion 659 259 468 1 2 8 4 6 5 382 130 430 Center of Drainage Pipe 0 592 49 175 523 565 554 173 176 129 132 The drawing shows AY S195X AY P069X Basin Operation Angle Height of armrest lead...

Страница 22: ...g neck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY LUXIS AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dim...

Страница 23: ...eck cushion 259 468 1 2 8 Center of Drainage Pipe 0 49 175 565 554 173 176 129 132 The drawing shows AY ELI AY P069X Basin Operation Angle Height of armrest leading edge Sheet height Note The dimensio...

Страница 24: ...ration Be careful about the installation direction If the cushion is installed in the wrong direction it may contact the backseat Caution Seat side Basin side Execute the installation using the follow...

Страница 25: ...lumber cover and put it on the lumber 3 Place the lumbar cover with the cutout side facing down and align the cover and the corner of the lumbar component Fit the cover over the lumbar part in the se...

Страница 26: ...he pipe form RS1 NRS When changing the pipe from NRS the height of the riser drainage pipe must be adjusted to 110 mm Floor Surface of Tile or Glass Finish The tiles or glass of the floor surface will...

Страница 27: ...27...

Страница 28: ...28 1E02VYA0 NOTE 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan Printed in Japan TAKARA BELMONT CORPORATION TEL 06 6213 5945 FAX 06 6212 3680...

Отзывы: