- 15 -
TEMPERATURE SETTINGS
There are 4 preset temperatures that you can
select from by adjusting the dipswitch settings
on the computer board. The temperature has
been preset at the factory to122ºF (50ºC). The
computer will electronically control this
temperature. At a fixture, mix cold water with
hot to get the water temperature you desire. If
you desire a hot water temperature other than
the 4 preset settings, please purchase the
optional temperature remote controller (part
No. TM-RE10). With this optional TM-RE10
you can set the temperature from 99ºF to
182ºF. Please carefully read the instructions
prior to installing the TM-RE10 as failure to do
so could damage the temperature controller
and/or the appliance, which will void the
warranty.
Hot Water Output Temperature Setting:
With the FLASH T-H1 Appliance, the output
hot water temperature can be adjusted either
manually from the main computer board’s
dipswitches or with the optional remote
controller (Part TM-RE10, from 99
°
F to 182
°
F).
The dipswitches can set four hot water output
temperatures 113
°
F, 122
°
F, 140
°
F, and 182
°
F
(the factory set temperature is 122
°
F).
Temperature setting
Only change black switches. Do not adjust any another switches
.
Installation setting
Only change black switches. Do not adjust any another switches
.
.
Содержание T-H1
Страница 25: ... 25 Comp Components Diagram Case assembly Neutralizer assembly ...
Страница 26: ... 26 Burner assembly ...
Страница 27: ... 27 Water way assembly ...
Страница 28: ... 28 Computer board assembly ...