Accessories
Check that all parts listed below were included
with the unit.
Installation Manual, Warranty Card and
Optional Part Information
Optional Items
1. TM-RE10 Temperature Remote Controller
The TM-RE10 Temperature Remote Controller
has two functions, it allows the output
temperature from the T-M1 to be adjusted
within the range of 95 °F to 167 °F, and it also
works as a diagnostic tool that will give a
concise error code whenever there is a
problem with the unit. The temperature options
are 95°F, 100°F, 102°F, 104°F, 106°F, 108°F,
109°F, 111°F, 113°F, 115°F, 117°F, 122°F,
131°F, 140°F, 158°F, 167°F, and 176°F for
180°F. See the trouble shooting section for
information on possible error codes.
2. TK-TV01 Vent Terminator
This terminator can be used where a T-M1 is
going to be vented out through a wall. This is a
CSA approved part of the unit. Connect a
Category III Stainless vent pipe from the top of
the unit to the backside of this terminator to
exhaust flue gases through the wall without a
thimble. Install vent terminator in accordance
with manufacturer’s installation instructions
and any applicable local codes.
3. TK-TV03 Vent Damper
The TK-TV03 Vent Damper prevents the
backflow of air through the exhaust vent. This
is CSA approved part of the unit. This helps
prevent harmful exhaust gases from entering
the home, as well as helping to prevent the
units from freezing in areas where cold air can
be blown into the exhaust system. Install vent
damper according to manufacturer’s
installation instruction, and any applicable
codes.
4. TM-TV06 Vent Cap
The TM-TV06 Vent Cap is for outdoor
installation with the T-M1 water heater. The
cap is installed on the top of the unit, instead of
connecting an exhaust vent. The cap will
prevent any debris that might be in the
environment from entering the unit and causing
damage or a fire hazard, as well as preventing
rain or other weather from entering the unit.
OUTDOORS INSTALLATION
Follow all local codes and in the absence of
local codes, follow the National Fuel Gas Code
ANSI Z221.23 in USA or in Canada CAN/CGA
B149.1 or .2 Installation of Gas Burning
Appliances.
Locate the water heater in an open, unroofed
area, and maintain the following minimum
clearances. MOBIUS water heater is wall
hanging installation only.
Piping side (Bottom)
12”
Front (Maintenance
space)
24”
Back of heater
1”
Top of heater
36”