![Takagi Mobius T-M1 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/takagi/mobius-t-m1/mobius-t-m1_installation-and-operating-instructions-manual_814335013.webp)
Recommend Gas pipe size for
MOBIUS Water Heater
Distance from Gas Meter
Pipe Size (inches)
0' - 20'
3/4"
20' - 80'
1"
80' - 300
1-1/4"
NOTE:
These Tables are for Natural Gas (0.60
Specific Gravity) and based on Pressure Drop
of 0.5 Inch water columns. This table is Gas
piping supply straight to the water heater
without any tab to other gas appliance.
Natural Gas Supply Piping
Based on 0.60 specific gravity for natural gas at .5” WC pressure drop
DOE standard is 1100 BTU per cubic ft. of natural gas
Pipe
Size
Cubic Feet of Natural Gas
Length
10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’
125’
150’
200’
½” 174
119 96 82 73 66 61 56 53 50 44 40
34
¾” 363 249 200 171 152 138 127 118 111 104 93 84 72
1” 684 470 377 323 286 259 239 222 208 197 174 158
135
1
¼” 1404 965 775 663 588 532 490 456 428 404 358 324
278
1
½” 2103
1445
1161
993 880 798 734 683 641 605 536 486
416
2”
4050 2784 2235
1913 1696
1536
1413
1315
1234
1165 1033 936
801
Propane Supply Piping
Based on 11” WC supply pressure
Pipe
Size
kBTU of Propane
Length
10’ 20’ 30’ 40’ 50’ 60’ 70’ 80’ 90’ 100’
125’
150’
200’
½” 275
189
152
129
114
103
96 89 83 78 69 63 55
¾” 567 393 315
267 237
217
196
185
173
162 146 132
112
1” 1071 732 590
504 448
409
378
346
322
307 275 252
213
1
¼” 2205
1496
1212
1039 913
834
771
724
677
630 567 511
440
1
½” 3307
2299
1858
1559
1417
1275
1181
1086
1023
976 866 787
675
2”
6221 4331 3465
2992 2646
2394
2205
2047
1921
1811 1606 1496
1260
Water Connections
An approved manual water control valve (water
shutoff valve) must be placed on the cold water
supply line. All soldering materials and piping
materials must be suitable with potable water.
If the water heater is installed in a closed water
system, such as one having a backflow
preventer in the cold water supply line, must be
provided to control thermal expansion. Contact
the water supplier or local plumbing inspector
on how to control this situation.
After installation of water heater is complete,
purge the water line to remove all the debris
and air from the line. Failure to or not doing so
may cause damage to the heater. There is a
wire mesh filter to trap debris from entering
your heater. This will need to be cleaned
periodically for long life expectance.