18
13.
NORMAL OPERATION
• Flow rate to activate the water heater
: 2.3 LITRES per minute
• Flow rate to keep the water heater running : 1.8
LITRES per minute
Notice
WITHOUT REMOTE CONTROLLER
1
.
Open a cold water tap.
2
.
Mix hot water with the cold
water to get the suitable temper-
ature water.
3
.
Close the water taps.
NOTE:
The water temperature is set at
50/60 °C
from the factory*. If you want to change the set
temperature of hot water without remote controller, refer to diagram below.
WARNING
• Water temperatures above 50 °C can cause severe burns or death from scalding.
Children, the disabled and the elderly are at a high risk of being injured. Feel the
water temperature before bathing or showering. Do not leave children, disabled
persons, or the elderly unsupervised. The Australian Standards AS 3498 gives full
details of the requirements for supply of controlled temperature to ablution out-
lets (bathrooms) and is required to be conformed to under all plumbing codes
within Australia.
• For continued safety of this appliance, it must be installed and maintained in accord-
ance with the manufacturer’s instructions.
40°C
60°C
MODEL
DEFAULT
60°C
45°C
55°C
Temperature settings
50°C
MODEL
DEFAULT
50°C
OFF
ON
TMP1
TMP2
TMP3
8 7 6
TMP1
TMP2
TMP3
OFF
ON
8 7 6
TMP1
TMP2
TMP3
OFF
ON
8 7 6
TMP1
TMP2
TMP3
OFF
ON
8 7 6
TMP1
TMP2
TMP3
OFF
ON
8 7 6
WARNING
• Turn off the power supply to the water heater before changing the DIP switch set-
tings.
• Only change the switches with dark squares.
• DO NOT adjust other switches.
• DO NOT mistake on-direction for off-direction of the switch.
*NOTE:
50 °C models: GS-20W-AU5
GS-26W-AU5
60 °C models: GS-20W-AU6
GS-26W-AU6
The set temperature of
55/60 °C is not available for
50 °C models.