TAIYO ELECTRIC IND.CO.,LTD.
8
TAIYO ELECTRIC IND.CO.,LTD.
KEY
LOCK
RX-822
HEAT
SLEEP
1.TEMP.
˚C
AS
HEAT
SLEEP
2.TEMP.
˚C
①
①
⑥
③
②
②
④
④
⑤
⑦
⑦
⑧
⑨
DUAL PORT SOLDERING STATION
2
1
③
1. HEAT lamp
Lights up when the heater is ON.
2. SLEEP lamp
Flashes while setting the SLEEP function. The flashing will get faster 30
seconds before going into SLEEP mode. Lights up when the unit enters
SLEEP mode.
3. TEMP. display
When the power is turned ON or when SLEEP mode is exited, the TEMP
display shows the tip temperature rise to the set temperature. The TEMP
display shows the set temperature when it is reached.
4. ALARM lamp
(to the right of the last digit in the temperature display)
Flashes when the tip temperature is within the DIF range.
Turns off when the tip temperature is out of the DIF range.
Flashes when the tip temperature is out of the upper and lower tempera-
ture limits.
5. KEY LOCK lamp
Flashes while setting the Key Lock function.
Flashes when the unit is in Key Lock mode.
6. KEY LOCK key
Use to set the Key Lock function.
Use to lock and unlock the keypad.
7. SETTING key
This key is used to set the temperature and parameters.
8. DOWN key
This key is used to reduce the temperature and change the parameter.
9. UP key
This key is used to increase the temperature and change the parameter.
■
Operation Panel