Taiwan Commate Computer Inc. PV-DDR Скачать руководство пользователя страница 1

PV-DDR

Motherboard

 

User’s Manual

Product Name: PV-DDR
Manual Revision: English,  1.0

 

Trademarks

 
Intel, Celeron, Socket 370 and Pentium III are trademarks of Intel
Corporation
 
VIA is a registered trademark of VIA Technologies, Incorporated.
 
Award is a trademark of Award Software International Inc.
 
MS-DOS, Windows 95, Windows 98, Windows ME, Windows
2000 and Windows NT are registered trademarks of Microsoft
Corporation
 
Novell is a trademark of Novell Corporation
 
All other brand and product names are trademarks or registered
trademarks of their respective companies.
 

Table of Contents

 
Chapter 1.  Introduction
 

                                1.1      Product Overview
                                1.2      Features
                                1.3      Specifications
                                1.4      Content
                                1.5      System Board Layout

Содержание PV-DDR

Страница 1: ...trademark of Award Software International Inc MS DOS Windows 95 Windows 98 Windows ME Windows 2000 and Windows NT are registered trademarks of Microsoft Corporation Novell is a trademark of Novell Cor...

Страница 2: ...Connector 2 4 3 System and CPU Fan Connectors 2 4 4 Wake On LAN Connector 2 4 5 Wake On Modem Connector 2 4 6 Floppy Disk Drive Connector 2 4 7 Primary Secondary IDE Connector 2 4 8 PS 2 Mouse Port 2...

Страница 3: ...1 Windows 95 Installation 4 4 2 Windows 98 Installation 4 4 3 Windows ME Installation 4 4 4 Windows 2000 Installation 4 4 5 Windows NT 4 0 Installation Chapter 1 Introduction 1 1 Product Overview Tha...

Страница 4: ...4X graphics card Support Advanced Configuration Power Interface ACPI BIOS Green feature function and Plug Play Flash ROM Support Desktop Management Interface DMI through BIOS RTC Wake Up Alarm Progra...

Страница 5: ...ndows 95 98 ME 2000 Windows NT MS DOS V6 22 OS 2 Novell Unix SCO UNIX USB Ports Six function ports support up to 127 peripheral devices Cable optional USB v1 1 and Intel Universal HCI v1 1 compatible...

Страница 6: ...s PCI v2 2 compliant One 32 bit AGP expansion slot AGP v2 0 compliant One Advanced Communications Riser ACR slot 1 4 Content The motherboard box contains the following items One Motherboard One IDE Ri...

Страница 7: ...Chapter 2 Hardware Setup...

Страница 8: ...e Keyboard Voltage JKBV WARNING Electronic parts are Static sensitive To prevent damage to the computer and its parts please take the following measures Work on a surface such as concrete linoleum or...

Страница 9: ...and put on JRTC 2 3 5 Connect ATX power cable back to connector ATXPWR 6 Turn on the power 7 While the system reboots press DEL key to set the BIOS setup 2 1 4 CPU Voltage Setting The motherboard sup...

Страница 10: ...N the level bar 2 3 Installation of Memory The motherboard has four 184 pin 64 bit DDR Double Data Rate Dual Inline Memory Module DIMM sockets You can install 2 5V Unbuffered PC1600 2100 DDR200 266 co...

Страница 11: ...ons ATXPWR ATX Power Connector CPUFAN CPU fan connector SYSFAN System fan connector JIR Infrared Connector Cable optional WOL1 Wake On LAN connector WOM1 Wake On Modem connector FDD Floppy Disk Drive...

Страница 12: ...eters and ASK IR 56Kbps An optional consumer infrared CIR set connects to the CIR and SIR connectors simultaneously for both wireless transmitting and remote control functions through one external inf...

Страница 13: ...tandby power 2 4 5 Wake On Modem Connector 3 pin WOM1 The connector connects to internal modem cards with a Wake On Ring output The connector powers up the system when a ring up packet or signal is re...

Страница 14: ...l If you have second IDE device to install in your system connect it as slave mode on the same channel and the third and fourth device can be connected on secondary channel as master and slave mode re...

Страница 15: ...e the parallel port and choose the IRQ through the Onboard Parallel Port setting in Integrated Peripherals of the COMS SETUP UTILITY 2 4 12 USB Connectors JUSB1 JUSB2 You can attach USB devices to the...

Страница 16: ...rding 2 4 17 ATAPI IDE Sony CD ROM Audio 4 pin JCDIN1 The ATAPI IDE Sony CD ROM Au dio connector is used to connect the audio cable from either an ATAPI IDE or Sony CD ROM drive for playback mixing an...

Страница 17: ...OS Setup Utility Copyright C 1984 2001 Award Software Standard CMOS Features Frequency Control Advanced BIOS Features Load Fail Safe Defaults Advanced Chipset Features Integrated Peripherals Load Opti...

Страница 18: ...tandard CMOS Features Screen CMOS Setup Utility Copyright C 1984 2001 Award Software Standard CMOS Features Date mm dd yy Fri Jan 1 1999 Item Help Time hh mm ss 1 28 42 Menu Level IDE Primary Master Q...

Страница 19: ...nual mode to define your own drive manually We recommend that you select Type AUTO for all drives The BIOS will auto detect the hard disk drive and CD ROM drive at the POST stage If your hard disk dri...

Страница 20: ...e 3 3 includes all AWARD enhanced functions The correct setting can enhance boot up efficiency You can assign system speed setup sequence typematic and system password setting You can enter F1 key for...

Страница 21: ...r any attempt to modify If an attempt is detected the BIOS will halt the system and prompt the warning message Select Disabled if you are installing a new operating system 3 3 2 CPU Internal External...

Страница 22: ...ill detect and verify operation of the floppy drive type 3 3 9 Boot Up Numlock Status The option allows the NumLock key to be activated after system boot up 3 3 10 Boot Up System Speed Default setting...

Страница 23: ...visor Password and User Password in the main CMOS Setup Utility Screen 3 3 16 OS Select for DRAM 64MB If you are using OS 2 operating system and installed memory is larger than 64MB You need to have t...

Страница 24: ...tem BIOS Cacheable Enabled Video RAM Cacheable Enabled Memory Parity ECC Check Disabled Move Enter Select PU PD Value F10 Save ESC Exit F1 General Help F5 Previous Value F6 Fail Safe Defaults F7 Optim...

Страница 25: ...this field has two setting options By SPD or HCLK 33M When the installed CPU is 100MHz this field has three setting options By SPD Host CLK or HCLK 33M When the installed CPU is 133MHz this field has...

Страница 26: ...D Value F10 Save ESC Exit F1 General Help F5 Previous Value F6 Fail Safe Defaults F7 Optimized Defaults 3 4 9 AGPAperture Size Choose 4 8 16 32 64 128 256MB Memory mapped graphics data structures can...

Страница 27: ...ability 3 4 15 AGP Master 1 WS Read This implements a single delay when reading to the AGP Bus By default two wait states are used by the system allowing for greater stability CMOS Setup Utility Copyr...

Страница 28: ...dress space to ISA expansion cards that specifically require this setting This makes the memory from 15MB and up unavailable to the system Expansion cards can only access memory up to 16MB 3 4 20 Syst...

Страница 29: ...roller All Enabled USB Keyboard Support Disabled IDE HDD Block Mode Enabled Move Enter Select PU PD Value F10 Save ESC Exit F1 General Help F5 Previous Value F6 Fail Safe Defaults F7 Optimized Default...

Страница 30: ...nterface where the errors occur Depending on the configuration of your IDE subsystem this field may not appear and it does appear when the Internal PCI IDE filed above is Disabled 3 5 3 Primary Second...

Страница 31: ...elds to Disabled 3 5 6 VIA 3043 OnChip LAN If you have ACR LAN card on board please set the field to Enabled CMOS Setup Utility Copyright C 1984 2001 Award Software SuperIO Device Onboard FDC Controll...

Страница 32: ...COM2 serial port connector and assign the resources to the infrared device If you have selected an IR mode use the following item UR2 Duplex Mode to define if the IR port is full duplex or half duple...

Страница 33: ...dling time for each sector 3 6 Power Management Setup Power management decreases power usage under the pre defined standby time range Figure 3 6 Power Management Setup Screen CMOS Setup Utility Copyri...

Страница 34: ...rives to shut off while in the Power Management modes 3 6 4 Suspend Mode System further shuts down all devices except for CPU itself This is the third level of Power Management 3 6 5 Video Off Option...

Страница 35: ...AC power failure the system will automatically power on Auto When power returns after an AC power failure the system will return to the state where you left off before power failure occurs If the sys...

Страница 36: ...he system Ctrl Fx The options are from Ctrl F1 to Ctrl F12 You can select a function key you would like to use to power on the system 3 6 12 VGA When set to On any event occurring at a VGA port will a...

Страница 37: ...esume Set this option to enable or disable the RTC Alarm to Wake Up the system which is set at soft Off 3 6 19 Date of Month Resume Time hh mm ss Set these options to specify the RTC Alarm time on Dat...

Страница 38: ...t C 1984 2000 Award Software PnP PCI Configurations PNP OS Installed No Item Help Reset Configuration Data Disabled Menu Level Resources Controlled By Auto ESCD X IRQ Resources Press Enter PCI VGA Pal...

Страница 39: ...Q 5 assigned to PCI Device IRQ 7 assigned to PCI Device Legacy ISA for devices IRQ 9 assigned to PCI Device compliant with the IRQ 10 assigned to PCI Device original PC AT bus IRQ 11 assigned to PCI D...

Страница 40: ...Integrated Peripherals menu When this item is Enabled the system automatically assigns an IRQ for the USB device connected to your system 3 8 PC Health Status Figure 3 8 PC Health Status CMOS Setup Ut...

Страница 41: ...d CPU These values refresh upon any key entry 3 8 4 CPUFAN SYSFAN Speed xxxxRPM The onboard hardware monitor is able to detect system fan speed CPU fan speed in Rotations Per Minute RPM These values r...

Страница 42: ...d Defaults Y N N Type Y and press Enter to load the Setup default values 3 12 Set Supervisor User Password You can assign modify or cancel password settings To modify highlight Set Supervisor Password...

Страница 43: ...utorun Program You can use the autorun menu of this CD driver disk Choose the model name to get driver and utility You can also get driver and utility from correct directory Please make sure the model...

Страница 44: ...p the midi output Please follow the steps below to setup MIDI instruments 1 1 Double Click Multimedia icon from Start Setting Control Panel 1 2 Select MIDI page and select Microsoft GS Wavetable SW Sy...

Страница 45: ...select Device Manager page 5 Double click Other devices 6 Double click PCI Ethernet Controller 7 Select Driver page 8 Click Update Driver button 9 Select Yes Recommended then click Next button 10 Clic...

Страница 46: ...ect the hardware from a list then click Next button 6 Select Network adapters from Hardware types list then click Next button 7 Click Have Disk button 8 Click on Browse and go to the directory where t...

Страница 47: ...ice recommended then click Next button 9 Select Specify a location then click Next button 10 Type in the correct drive and path then click OK button For example D VIA ACR LAN W2000 11 Click Next butto...

Страница 48: ...your system you will acquire network service 2 If you setup ACR LAN card after Windows NT was installed 1 Please copy LAN driver for NT to your HDD first For example copy D VIA ACR LAN WNT40 C NTDRV o...

Страница 49: ...7 Select Next button to continue Setup 8 You must answer a few more questions to continue Setup 9 Restarting your system you will acquire network service...

Отзывы: