TM8100/TM8200 Computer-Controlled Data Interface (CCDI) Protocol Manual
CCR
61
© Tait Electronics Limited
April 2007
2.8
CCR Commands
2.8.1
Summary and Examples
The messages in the following table are sent from the DTE to the RU.
In all cases, if the command is received without error by the RU and all the
parameters are valid, the command will be executed and the prompt will be
returned to the DTE. If an error arises, the DTE will be notified with an
appropriate response.
Examples
f0200D8
Enter ccr from ccdi
E005B
Exit - same effect as “^”
R0945320000087 Set Rx frequency to 453.2MHz
T0945320000085 Set Tx frequency to 453.2MHz
Q01PFE
Pulse command, returns “P” when minimum config
exists
P0111E
Set power to Very Low
P0141B
Set power to High
H01324
Set bandwidth to Wide
H01126
Set bandwidth to Narrow
A0406708E
Set Rx ctcss to 67Hz
A0400009B
Set Rx ctcss to 0Hz
B0406708D
Set Tx ctcss to 67Hz
B0400009A
Set Tx ctcss to 0Hz
C03023C5
Set Rx DCS to 23
C03000CA
Set Rx DCS to 0
D03023C4
Set Tx DCS to 23
D03000C9
Set Tx DCS to 0
S051234549
Dial 12345
Message
Cmd
Function
Rssxxxxxxxxxcc
R
Tssxxxxxxxxxcc
T
Hssxcc
H
Jssxxxcc
J
Assxxxxcc
A
Bssxxxxcc
B
Cssxxxxcc
C
Dssxxxxcc
D
Sssxxxxxcc
S
Isstplcc
I
Nsspxxxxxcc
N
Pssxcc
P
Qssxcc
Q
Esscc
E