TB9300 Specifications Manual
Base Station Specifications
31
© Tait International Limited August 2022
1.6
Transmitter
The specifications in this section pertain only to the combination of a
TB9300 reciter with a 50 W or 100 W power amplifier.
General
Frequency bands
B2 band*
B3 band*
C1 band
C3 band
G4 band
H1 band*
H2 band*
H3 band*
H4 band*
H5 band
K4 band*
K8 band
L2 band
136 MHz to 156MHz
148 MHz to 174MHz
174MHz to 193MHz
216 MHz to 225 MHz
330 MHz to 380MHz
400 MHz to 440MHz
440 MHz to 480MHz
470 MHz to 520MHz
380 MHz to 420MHz
400 MHz to 470MHz
762 MHz to 776 MHz and 850 MHz to 870 MHz
757 MHz to 758MHz
927 MHz to 941MHz
* Note that these frequencies have reached end-of-life, and whilst currently supported, are no longer available for
the TB9300. They are available for the TB9400, where B2 and B3 bands can be replaced by the B1 band.
Frequency increments
B and C bands
G4, H, K and L2 bands
2.5 kHz and 3.125 kHz
5 kHz and 6.25 kHz
Frequency stability
±0.5 ppm –30°C to +60°C (–22 °F to +140 °F)
a. For K band (700 MHz), the internal frequency reference accuracy is inadequate, and an external reference must be
used. The stability of this reference should be better than 100 parts per billion. See
.
Output load impedance
50
Ω
nominal
Output power
50 W PA
Rated power
Range of adjustment
100 W PA
Rated power
Range of adjustment
50 W
5 W to 50 W in 1 W steps
100 W
10 W to 100 W in 1 W steps
Output power accuracy
±0.5 dB into a 50
Ω
load
b. Within normal operating voltages and temperatures; measured directly on PA output.
Duty cycle
100% at maximum rated output power
(+140 °F) ambient temperature
c. Measured directly on PA output.