Reciter Circuit Description
TB8100 Service Manual
© Tait Electronics Limited September 2006
Digital Outputs
The digital outputs are open collector outputs. The maximum current
rating of these outputs is 100mA. The maximum voltage that should be
applied to these outputs is 30V.
Tx Relay Driver
Output
The
Tx relay driver output is an open collector output. The maximum
current rating of this output is 250mA. The maximum voltage that should
be applied to this output is 30V.
Opto-coupled
Keying Input
This input operates in parallel with the Tx Key input. Although it has the
same functionality as the Tx Key input, it is electrically isolated. The input
may be driven with a voltage in the range
±
10V to
±
60V. The input
current is regulated to 10mA.
Opto-coupled Gate
Output
This output operates in parallel with the Rx Gate output. Although it has
the same functionality as the Rx Gate output, it is electrically isolated. The
maximum output current is 120mA. The maximum voltage that should be
applied across this output is
±
350V.
Third-party
Connector
The third-party connector provides access to audio, keying, gating and
digital I/O signals to allow the integration of third-party modules such as
scramblers.
RS-232 Serial Port
The TaitNet RS-232 system interface board is fitted with an RS-232 serial
port (9-way female D-range connector). Note that when a reciter fitted
with a TaitNet RS-232 system interface board is used in a TB8100 base
station, the RS-232 port on the control panel is disabled. In this situation
you must connect to the RS-232 port at the rear of the reciter.
Ethernet Adaptor
The TaitNet Ethernet system interface board is fitted with an Ethernet
adaptor which provides Ethernet connectivity via a standard RJ45
connector. Note that when a reciter fitted with a TaitNet Ethernet system
interface board is used in a TB8100 base station, connection via the RS-232
port on the control panel is only available when the base station first powers
up. Refer to Application Note TN-1142-AN for more details.
Power Supplies
The system interface board is powered via the 40-way flexible connection
to the reciter.
Содержание TB8100
Страница 1: ...TB8100 base station Service Manual MBA 00016 02 Issue 2 September 2006...
Страница 8: ...8 TB8100 Service Manual Tait Electronics Limited September 2006 19 Subrack Servicing 287 Glossary 295...
Страница 62: ...62 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 64: ...64 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 66: ...66 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 68: ...68 Reciter Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 98: ...98 Reciter Fault Finding TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 108: ...108 Reciter Board Replacement TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 110: ...110 Reciter Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 112: ...112 Reciter Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 124: ...124 Power Amplifier Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 126: ...126 Power Amplifier Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 172: ...172 Power Amplifier Fault Finding TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 178: ...178 Power Amplifier Disassembly and Reassembly TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 200: ...200 Power Amplifier Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 212: ...212 Power Management Unit Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 214: ...214 Power Management Unit Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 248: ...248 Power Management Unit Fault Finding TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 268: ...268 Power Management Unit Spare Parts TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 276: ...276 Control Panel Circuit Description TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 288: ...288 Subrack Servicing TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 294: ...294 Subrack Servicing TB8100 Service Manual Tait Electronics Limited September 2006...
Страница 306: ...306 TB8100 Service Manual Tait Electronics Limited September 2006...