Tait T800 - 22 - 0x00 Скачать руководство пользователя страница 41

T A I T

Radio Communications

Christchurch

New Zealand

DRAWING:     T800-22-0x20  RACKFRAME

TITLE:

RACK, SNGL<100W, (MONITOR)

Drawn

Date

Checked

AMM

12/1/99

ABB

AMM

29/11/99

ABB

AMM

8/3/99

ABB

AMM

25/8/99

ABB

Version

1

4

2

3

Original

Drg name changed

Parts list added

Drg No changed, Ref added

FRONT VIEW

REAR VIEW

OPTIONAL

DUPLEXER

OPTIONAL

CHANNEL

PANEL

Rx/Tx Monitor

T800//

Supply

Volume

Volts

Rx Signal

Rx Line

Tx Line

Fwd Pwr

Rev Pwr

Off

Speaker Panel

T800//

Excellence in Radio
Communications

T800//

Receiver

T800//

Line
level

Supply

Monitor
Volume

Monitor

Mute

Off

On

Gating

Sensitivity

Gate

Exciter

Line

Sensitivity

Supply

On

Microphone

Carrier

T800//

T800//

Power

Low forward power

High reverse power

Supply

Power Amplifier

T800//

Power Supply

Power

On

Standby

Overload

OPTIONAL

TRANSMITTER

OPTIONAL

BLANK
PANEL

FAN (OPTIONAL)

1

X800-90-0000

POWER RAIL (STANDARD)

SECTION 4

REFERENCE

SECTION 4

SECTION 4

SECTION 4

SECTION 8

SECTION 3

SECTION 4

SECTION 8

ITEMS SUPPLIED AS STANDARD

PART NUMBER

DESCRIPTION

1

T800-22-0004

RACK, FRAME ONLY, ASSEMBLED

QTY

1

T800-41-0002

DOUBLE GUIDE KIT

1

T800-45-0000

GUIDE PA 50W KIT

1

T800-44-0000

T800 PS GUIDE KIT

1

T800-15-0000

SPEAKER / PROGRAM PANEL

1

T800-50-0000

BACKPLANE

1

T800-40-0000

FIXING KIT ONLY

1

T800-40-0001

BLANKING BRACKET / FRONT PANEL

1

T800-43-0001

GUIDE KIT T1500/300 SINGLE 'D'

1

T800-60-0000

PERSONALITY BOARD

SECTION 4

SECTION 5

SECTION 6

EARTH

STUD

FUSE

TB1

OUTPUT

ONLY 13.8V

MAX

2 AMPS

PA

Receiver

Exciter

Rx/Tx MON

T818-01-0000

T800

-50-0000

T800-60-0000

Power

Supply

Output
13.8V
25A
Max.

+

-

1
2
3
4
5

Speaker

Panel

FAN (OPTIONAL)

REFER TO SECTION 3

OF THE

REFERENCE GUIDE

FOR

POWER RAIL OPTIONS

Содержание T800 - 22 - 0x00

Страница 1: ...T800 Series II Conventional Equipment Reference Guide M800RACK 00 100...

Страница 2: ...Conventional T800 Equipment Questionnaire Order Number System Rack and Function Cross Reference Chart Rack Components Weights Section 2 Rack Configurations Section 3 Rack Power Supply Options Section...

Страница 3: ...T800 Series II Conventional Equipment Reference Guide Introduction...

Страница 4: ...ack to produce combinations for customised solutions Tait System Solutions are open ended As well as information about the equipment there is also an order form and detailed instructions on how to fil...

Страница 5: ...ation In the interests of improving the performance reliability or servicing of the equipment Tait Electronics Limited reserve the right to update the equipment or this document or both without prior...

Страница 6: ...ere will be a need for Transmitter and Receiver to be in different bands this will not affect the Rackframe required ENSURE EQUIPMENT STATED IS TYPE APPROVED FOR COUNTRY OF USE PART 03 DO YOU KNOW WHA...

Страница 7: ...Series II Ensure type ordered are Type Approved for Country of use PART 05 DO YOU KNOW THE FREQUENCIES This information can be helpful as sometimes the auxiliary equipment can be frequency dependant i...

Страница 8: ...up procedure in the appropriate equipment manual and the frequency frequencies required are as stated in PART 05 If no frequencies are stated in Part 05 then the equipment is to be Set up on TEST fre...

Страница 9: ...xx xxxx 800 880Mhz T88n xx xxxx 174 225Mhz T37n xx 400 440Mhz T85n xx xxxx 870 960Mhz T88n xx xxxx ARE REQUIRED MODULES TYPE APPROVED COUNTRY OF USE PART 03 DO YOU KNOW WHAT IS REQUIRED PER RACK Descr...

Страница 10: ...XILLIARY EQUIPMENT Description OPTION REQUIRED Qty Part Number For Freq Mhz Power Monitor Kit Automatic Changeover Unit Installation Kit PART 07 ANCILLIARY EQUIPMENT Description Qty Part Number Cabine...

Страница 11: ...Duration Secs Number of Channels Audio Response Single Pre emphasised Freq MHz Flat Multiple Special Modifications Pattern Required No Yes Line Level dBm Refer to Part 08 PART 12 RECEIVER PARAMETERS S...

Страница 12: ...T800temp V11 doc Issued 09 Sept 1999 Page 4 of 4 SYSTEM BLOCK DIAGRAM OPTIONAL...

Страница 13: ...ons Each Rack is fully wired and set up for AC or DC power supply options Refer to Section 3 A Speaker Programming Port Panel and all required Blank Panels and are fitted as standard to each rack as r...

Страница 14: ...0XX T818 01 0000 TA087 01 0000 TA387 01 TA136 02 0000 0 1 2 No Duplexer Fitted 50 Watt Duplexer Fitted Coaxial Relay This item code is always set to 0 for Slimline configurations If Duplexer item code...

Страница 15: ...0x00 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x06 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x10 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x11 2 2 2 2 2 2 2 2 2 2 T800 22 0x12 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 22 0x14 2...

Страница 16: ...t 25W Transmit Receive only Dual system Single system Module Function 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 25 0000 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 25 0001 2 2 2 2 2 2 2 2 2 2 2 2 2 2 T800 25 0002 2 2...

Страница 17: ...05 T8n7 Exciter 2 05 50W Power Amplifier 3 20 100W Power Amplifier 3 55 T80n Power Supply 2 30 Circuit breaker 0 50 DC Converter Module 0 90 TA136 Alarm Unit 0 85 T818 Monitor 0 95 TA807 Channel Panel...

Страница 18: ......

Страница 19: ...T800 Series II Conventional Equipment Reference Guide Rack Configuration...

Страница 20: ...ttery Configuration Options Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0010 installation kit microphone DC converter Mechanical Character...

Страница 21: ...nications T800 Excellence in Radio Communications T800 Speaker Panel T800 OPTIONAL TRANSMITTER OPTIONAL BLANK OPTIONAL DUPLEXER FAN OPTIONAL OPTIONAL BLANK ITEMS SUPPLIED AS STANDARD PART NUMBER DESCR...

Страница 22: ...n Options Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0010 installation kit Microphone DC converter Mechanical Characteristics 5 Rack Unit...

Страница 23: ...s T800 Excellence in Radio Communications T800 Excellence in Radio Communications T800 FRONT VIEW REAR VIEW ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY ASSEMBLED...

Страница 24: ...only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfac...

Страница 25: ...cellence in Radio Communications T800 Speaker Panel T800 OPTIONAL TRANSMITTER OPTIONAL BLANK OPTIONAL DUPLEXER OPTIONAL CHANNEL PANEL FAN OPTIONAL OPTIONAL BLANK 1 X800 90 0000 POWER RAIL STANDARD SEC...

Страница 26: ...nterface Power Supply Options x 0 AC only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Channel Pa...

Страница 27: ...e Monitor Mute Off On Gating Sensitivity Gate Receiver T800 Line level Supply Monitor Volume Monitor Mute Off On Gating Sensitivity Gate OPTIONAL CHANNEL PANEL OPTIONAL or BLANK Receiver Speaker Selec...

Страница 28: ...ply Options x 0 AC only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Channel Panel Fans single or...

Страница 29: ...me Monitor Mute Off On Gating Sensitivity Gate OPTIONAL CHANNEL PANEL OPTIONAL or BLANK Excellence in Radio Communications T800 Speaker Panel T800 Receiver Speaker Select 1 6 2 5 3 4 1 X800 90 0000 PO...

Страница 30: ...d External DC x 3 AC and Battery x 4 External DC and Battery Not Available see T800 22 0x16 x 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans single or double Interfaces to C...

Страница 31: ...rrier T800 T800 Power Low forward power High reverse power Supply Power Amplifier FAN OPTIONAL FAN OPTIONAL 1 X800 93 0002 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION...

Страница 32: ...ery x 4 External DC and Battery Not Available see T800 22 0x17 x 5 AC and External DC and Battery Configuration Options Channel Panel Individual Speaker Programming panels Duplexer Coaxial Relay Fans...

Страница 33: ...y Gate Transmitter Line Sensitivity Supply On Microphone Carrier T800 Speaker Panel T800 RX 1 RX 2 O F F O F F Excellence in Radio Communications T800 OPTIONAL SPEAKER T800 15 0000 OPTIONAL DUPLEXER A...

Страница 34: ...x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans single or double Interfaces to C...

Страница 35: ...ute Off On Gating Sensitivity Gate Transmitter Line Sensitivity Supply On Microphone Carrier T800 Speaker Panel T800 RX 1 RX 2 O F F O F F 1 X800 22 0015 POWER RAIL STANDARD SECTION 4 REFERENCE SECTIO...

Страница 36: ...ernal DC Not Available x 3 AC and Battery Not Available x 4 External DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Coaxial Relay Fans single or double Interface...

Страница 37: ...High reverse power Supply Power Amplifier Speaker Panel T800 RX 1 RX 2 O F F O F F FAN OPTIONAL FAN OPTIONAL 1 X800 91 0002 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 8 SECTI...

Страница 38: ...800 22 0x14 x 3 AC and Battery Not Available see T800 22 0x14 x 4 External DC and Battery x 5 AC and External DC and Battery Not Available see T800 22 0x14 Configuration Options Channel Panel Duplexer...

Страница 39: ...n Gating Sensitivity Gate Transmitter Line Sensitivity Supply On Microphone Carrier T800 Excellence in Radio Communications T800 RX 1 RX 2 O F F O F F OPTIONAL DUPLEXER and or CHANNEL PANEL 1 X800 91...

Страница 40: ...ery Not Available x 5 AC and External DC and Battery Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0011...

Страница 41: ...0 Power Supply Power On Standby Overload OPTIONAL TRANSMITTER OPTIONAL BLANK PANEL FAN OPTIONAL 1 X800 90 0000 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 3...

Страница 42: ...ternal DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx us...

Страница 43: ...rrier T800 T800 Circuit Breaker On 1 0 Off Supply 12V 1 X800 22 0121 POWER RAIL STANDARD SECTION 5 SECTION 3 ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY ASSEMBLED...

Страница 44: ...ternal DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx us...

Страница 45: ...ier T800 T800 Power Low forward power High reverse power Supply Power Amplifier 1 SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 6 SECTION 3 SECTION 4 SECTION 8 SECTION 8 SECTION...

Страница 46: ...n Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0011 installation kit microphone DC converter Mechanical Characteristi...

Страница 47: ...LANK OPTIONAL DUPLEXER OPTIONAL CH PNL FAN OPTIONAL OPTIONAL TRANSMITTER OPTIONAL BLANK 1 X800 93 0000 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION...

Страница 48: ...on Options Channel Panel Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00 xxxx using TA703 11 0011 installation kit microphone DC converter Mechanical Characterist...

Страница 49: ...PTIONAL OPTIONAL TRANSMITTER OPTIONAL BLANK 1 X800 93 0000 POWER RAIL STANDARD SECTION 4 REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION 5 SECTION 3 SECTION 4 SECTION 8 1 T800 50 0000 BACKPL...

Страница 50: ...ee T800 23 0x01 x 1 External DC only x 2 AC and External DC Not Available x 3 AC and Battery Not Available x 4 External DC and Battery x 5 AC and External DC and Battery Not Available Configuration Op...

Страница 51: ...r Transmitter TB Receiver Line Level Supply Monitor Volume Monitor Gating Sensitivity Gate On Off T800 Transmitter Line Sensitivity Supply Exciter Out On Microphone Carrier T800II Slimline ITEMS SUPPL...

Страница 52: ...1 External DC only Not Available see T800 23 0x00 x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery Not Available x 5 AC and External DC and Battery Configuration Options Coaxial R...

Страница 53: ...Power Supply TB Receiver Line Level Supply Monitor Volume Monitor Gating Sensitivity Gate On Off T800 Transmitter Line Sensitivity Supply Exciter Out On Microphone Carrier T800II Slimline ITEMS SUPPL...

Страница 54: ...interface Battery Isolation Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modules Top Mounting Duplexer Tray Size...

Страница 55: ...T800 15 0000 SPKR PROG PNL or TA087 01 0000 100 CHANNEL CHANNEL PANEL or TA387 01 0000 10 CHANNEL CHANNEL PANEL EXTERNAL DC BATTERY OPERATION TALK THROUGH BASE STATION REPEATER FUSE 10A T800 50 0001 D...

Страница 56: ...fuse Backplane interface Battery Isolation Switch Talk Through Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modu...

Страница 57: ...100 CHANNEL CHANNEL PANEL or TA387 01 0000 10 CHANNEL CHANNEL PANEL T800 Power Supply Power On Standby Overload EXTERNAL DC BATTERY OPERATION TALK THROUGH BASE STATION REPEATER Output 13 8V 25A Max 1...

Страница 58: ...ce Battery Isolation Switch Talk Through Switch Configuration Options Channel Panel Duplexer Coaxial Relay Antenna Mechanical Characteristics Portable case to house up to 4 modules Top Mounting Duplex...

Страница 59: ...BATTERY OPERATION TALK THROUGH BASE STATION REPEATER Exciter Line Sensitivity Supply On Microphone Carrier T800 T800 Power Low forward power High reverse power Supply Power Amplifier T800 15 0000 SPKR...

Страница 60: ...2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 0...

Страница 61: ...wer Aux 0 Fwd Power Aux 1 Low Battery Aux 2 Line Fail Aux 3 Programming Port Clear Alarms Test 3 sec Remote Alarm T800 Talk Through Base Station Monitor On Off Monitor Volume Mode Toggle Rev Power Aux...

Страница 62: ...ternal DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Duplexer Coaxial Relay Fans single or double Interfaces to Changeover Module TA703 00...

Страница 63: ...DUPLEXER Remote Alarm T800 Talk Through Base Station Monitor On Off Monitor Volume Mode Toggle Rev Power Aux 0 Fwd Power Aux 1 Low Battery Aux 2 Line Fail Aux 3 Programming Port Clear Alarms Test 3 s...

Страница 64: ...DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Duplexer Coaxial Relay Fans single or double Interfaces to Change...

Страница 65: ...forward power High reverse power Supply Power Amplifier OPTIONAL TRANSMITTER OPTIONAL BLANK OPTIONAL BLANK OPTIONAL BLANK Excellence in Radio Communications T800 OPTIONAL TRANSMITTER OPTIONAL BLANK 1...

Страница 66: ...ons x 0 AC only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Fans single or double microphone DC...

Страница 67: ...sitivity Supply On Microphone Carrier T800 OPTIONAL DUPLEXER BEHIND SPK PROG PANEL OPTIONAL DUPLEXER OPTIONAL BLANK ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY AS...

Страница 68: ...C only x 1 External DC only x 2 AC and External DC x 3 AC and Battery x 4 External DC and Battery x 5 AC and External DC and Battery Configuration Options Fans single or double microphone DC converter...

Страница 69: ...upply Power Amplifier Excellence in Radio Communications T800 Speaker Panel T800 OPTIONAL DUPLEXER OPTIONAL BLANK ITEMS SUPPLIED AS STANDARD PART NUMBER DESCRIPTION 1 T800 22 0004 RACK FRAME ONLY ASSE...

Страница 70: ...e x 1 External DC only x 2 AC and External DC Not Available x 3 AC and Battery Not Available x 4 External DC and Battery x 5 AC and External DC and Battery Not Available Configuration Options Fans sin...

Страница 71: ...ume Monitor Mute Off On Gating Sensitivity Gate Exciter Line Sensitivity Supply On Microphone Carrier T800 1 X800 91 0002 POWER RAIL STANDARD REFERENCE SECTION 4 SECTION 4 SECTION 4 SECTION 8 SECTION...

Страница 72: ...T800 Series II Conventional Equipment Reference Guide Rack Power Supply Options...

Страница 73: ...000RAIL 100W AC X DC BATfor1supply X800 90 0001RAIL 2x25W ACfor2supply X800 91 0001RAIL 2x25W AC X DCfor2supply X800 92 0001RAIL 2x25W ACfor2supply X800 93 0001RAIL 2x25W AC BATfor2supply X800 94 0001...

Страница 74: ...TTERY BACK UP FUSE TB1 OPTIONAL POSITION OUTPUT ONLY 13 8V MAX 2 AMPS DIODE PACK EARTH STUD DC INPUT FUSE TB1 OUTPUT ONLY 13 8V MAX 2 AMPS EARTH STUD DC INPUT FUSE TB1 OUTPUT ONLY 13 8V MAX 2 AMPS DIO...

Отзывы: