5
Purpose of Use
This product is a cooling cabinet for exclusive use indoors and is fabricated to keep wet
towels, etc. cool. Should you wish to use it for any other purpose, please contact and
consult with TAIJI & Co.,LTD.
This product keeps towels, etc. cool (approximately 7
o
C to 10
o
C) within the cabinet by
the performance of the Peltier thermoelectronic device installed within the cabinet.
(This is the temperature at the center of the cabinet when the ambient temperature is 25
o
C
and the cabinet is not tightly packed.)
* Peltier thermoelectronic device is a heat exchanging unit using a Peltier element, a sort
of semi-conductor.
Operational Mechanism
Designation of Parts
Power cord
6
7
Sequence of Usage
Pre-use Instructions
1. In case the inner box is moist or there are any foreign substances, wipe clean
with a dry towel, etc.
* Any remaining moisture, etc. could cause failure or malfunction.
2. Put in moist rolled towels, etc. in the inner box. In the event the amount of towels,
etc. put into the cabinet is low, place them flat and as far apart as possible.
* The interior of the cabinet becomes cool from the backside.
* It is recommended that moist towels are placed individually in polyethylene wrapper
from a sanitary viewpoint.
* “COOLCABI” is a cooling cabinet and takes time to cool. Therefore, switching on well
in advance or prior cooling of towels, etc. to be placed in the unit is advised.
3. Close the door tightly and switch on. The Peltier thermoelectronic device is activated
and cooling commences. (Power pilot lamp is lit and exhaust fan rotates.)
* Empty drain tray frequently should water accumulate.
Post-use Instructions
8
Checking Prior to Use and Setting
1. Remove “COOLCABI” from packing carton and make sure that Warranty, Instruction Manual,
and accessories are included.
2. Set “COOLCABI” as follows:
●
At a place where it is flat and stable.
●
At a place where it is not affected by heat and avoid places where there is direct
sunlight, and near stoves, ranges, etc. (To be set away from such units by at
least 50cm.)
●
Away from moist places or where it is susceptible to being splashed with water.
●
Leave a space between “COOLCABI” and what may be placed next to it and make
sure there is airy space all around.
●
Do not block the intake and exhaust openings.
●
Leave a space of at least 10cm above and behind and at least 5cm on both sides.
Should it be set on a shelf, make an opening in the rear so that heat can escape.
(Rise in temperature around the intake opening will cause cooling temperature to
also rise and could cause failure.)
3. Grounding
Ensure correct grounding is secured to protect against electric shock. Consult with your
dealer for details.
4. Affixing drain tray
Hold both sides of drain tray horizontally and push in until firmly
inserted.
When water accumulates in the tray, remove and empty carefully.
Reinsert drain tray after being emptied.
Leave a space of at
least 10cm.
In case plastic parts of “COOLCABI” are touched with oily hands or the unit is placed
where oil is used in large quantities, make it a rule to wipe plastic parts daily with a
soft cloth soaked in neutral detergent solution diluted with hot water and dry off with a
soft cloth. Plastic parts could at times become deformed or crack under the influence
of oils, etc.
(4) Remove the plug from the electric outlet as soon as thunder is
heard. In the event of a nearby lightening strike, abnormal
current/abnormal voltage could infiltrate through the power source
line, etc. and possibly damage the product.
Eliminating
moisture
(5) Switch off and remove the plug from electric outlet when not in use.
If you do not, it could be the cause of an electric shock, electric
leakage fire, etc.
When not
in use
→
Removing
plug
→
(6) Do not use when the power cord or plug is damaged or when the
electric outlet is loose. Using under such conditions could cause
an electric shock, short-circuit, ignition, etc.
Forbidden
(8) Do not place heavy items on “COOLCABI” or place one’s weight on
it with its door open. Such could be the cause of damage or
toppling.
Forbidden
Space all
around
(9) Leave some space all around “COOLCABI.” (At least 10cm)
Lack of air circulation could cause failures.
(12) Wipe off moisture within the cabinet as well as body after use
and remove any foreign substances. Leaving towels inside will
cause discoloration and bad odor. It will also lead to
malfunctioning when used thereafter.
(13) Empty drain tray frequently. Accumulation of water could lead to
overflowing and cause bad odor.
(11) Do not leave the same towel within the cabinet for more than one
day. It could be the cause of discoloration and bad odor.
(10) Clean filters periodically. (About once a month) Higher
temperatures as a consequence of unclean filters could be
the cause of failures.
Filter
cleaning
(7) Do not place heavy items or water containers on top of
“COOLCABI.” Such could cause damage, injury, short-circuit,
electric shock, corrosion, failure, etc.
Forbidden
Forbidden
CAUTION
Plug
Rear panel
Outlet
Filter
(air intake)
x 3
Door back
Power
switch
Handle
Inner
box
Gasket
Power pilot
lamp
Body
Door
Drain tray
1. Switch off and remove plug from electric outlet.
2. Take out remaining towels, etc. and wipe inner box clean to remove residual
moisture.
3. Empty water accumulated in the drain tray. Wash clean when considerably stained.
4. Stains on the body should be wiped clean with a dry cloth or a tightly wrung
wet cloth.
* Use a neutral detergent when stains are severe. Do not use cleansers containing
abrasives or solvents such as paint thinners.
5. Leave the door of the cabinet open for a while for moisture to dry as a means to
prevent odors.
* Frequent cleaning of filters is a requisite for the cabinet’s best performance.
Check to see if exhaust outlet filter is clogged with dust, etc. If clogged, remove with a
soft toothbrush or eliminate dust with a vacuum cleaner or by other means.
Gasket
Insert gasket fully in the direction
indicated in case it becomes
detached
Power switch
(AC220-240V)
Product Code: TJCC8/TJCC8-220V
www.spaequip.com
T: 707-737-1100 F: 707-737-1150
Page 3 of 3