BYPASS VALVE 

The working parts of the bypass valve are the rotor assemblies that are contained under the bypass valve 

caps. Before working on the rotors, be sure that there is a closed shut-off valve ahead of the unit and the 

system is depressurized. Turn the red arrow shaped handles towards the center of the  bypass valve and 

back to the arrow direction several times to ensure rotor is turning freely. 

 

The nuts and caps are designed to be unscrewed or tightened by hand or with the Service Wrench, V3193. If 

necessary a pliers can be used to unscrew the nut or cap. Do not use a standard wrench to tighten or loosen 

nuts or caps. Do not place screwdriver in slots on caps and/or tap with a hammer. 

To  access  the  rotor,  unscrew  cap  and  lift  the  cap,  rotor  and  handle  out  as  one  assembly.  Rotating  the 

assembly as you pull it out will enable it to be removed more easily. There are three o-rings: one under the 

rotor cap, one on the rotor stem and one on the rotor seal. Replace worn o-rings. Clean rotor. Reinstall rotor. 

 

Before reinstalling the red arrow handles be sure that o-rings on both rotors face to the right when being 

viewed from the front when the handle pointers are pointing in the same direction as the control valve body 

arrows. Keep the handles pointed this way while tightening the valve caps. 

 

Caution: Since the handles can be pulled off, they could be accidentally reinstalled 180 degrees from their 

correct orientation. 

 

After  completing  any  valve  maintenance,  press  and  hold  NEXT  and  REGEN  buttons  for  3  seconds  or 

momentarily unplug power source jack (black wire). This resets the electronics and establishes the service 

piston position. The display should flash text, the software version (e.g. 164), and the cycle number before 

resetting the valve to the service position.

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание T../MA-BTB series

Страница 1: ...E PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN...

Страница 2: ...which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times salt dose exchange capacity and gallon capacity regeneration time...

Страница 3: ...gh them When moving through any displays or programmings if no buttons are pressed within five minutes the display returns to normal operating displays Any changes made prior to the five minute time o...

Страница 4: ...5CS Press UP or DOWN until FILL appears Press NEXT to go to Step 6CS Press REGEN to return to previous step Step 6CS Press UP or DOWN until END appears Press NEXT to exit Cycle Sequence Press REGEN t...

Страница 5: ...ss as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time T...

Страница 6: ...f no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail Press NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Press NEXT until SALT LE...

Страница 7: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Страница 8: ...sure relief valve Also be certain that local codes are not violated 4 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to room temperatures...

Страница 9: ...allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back siphoned into the conditioner INSTALLER SETTINGS Step 1I Press NEXT and UP simultaneously fo...

Страница 10: ...l the error or alert is reset by the user Press NEXT to exit Installer Display Setting Press REGEN to return to the previous step SET TIME OF DAY Time of day should only need to be set if the battery...

Страница 11: ...maining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Someti...

Страница 12: ...ACKWASH and the remaining time is counting down Unplug transformer to prevent valve from moving to the next cycle 3 Open the inlet handle of the bypass valve very slightly allowing water to fill the t...

Страница 13: ...12 REPLACEMENT PARTS...

Страница 14: ...13 REPLACEMENT PARTS...

Страница 15: ...14 REPLACEMENT PARTS...

Страница 16: ...15 REPLACEMENT PARTS...

Страница 17: ...16 REPLACEMENT PARTS...

Страница 18: ...17 INSTALLATION FITTING ASSEMBLIES...

Страница 19: ...orce on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the upper right corner Pressing to the left helps the drive gears mesh with the drive cap...

Страница 20: ...t may be used on black o rings but is not necessary Avoid any type of lubricants including silicone on red or clear lip seals Reinsert the drive cap assembly and piston into the spacer stack assembly...

Страница 21: ...ing dilute sodium bisulfite or vinegar Do not use a wire brush If necessary replace the flow control flow control retainer o ring or the elbow o ring Reseat the flow control so the rounded end with le...

Страница 22: ...tating the assembly as you pull it out will enable it to be removed more easily There are three o rings one under the rotor cap one on the rotor stem and one on the rotor seal Replace worn o rings Cle...

Страница 23: ...assy d Piston not in home position d Press NEXT and REGEN or momentarily unplug PC board power e Motor gears not fully engaged Motor wires broken Failed motor e Check motor and wiring f Center drive g...