TABLE OF CONTENTS 

 

Preinstallation Instructions for Dealer  

 

Specifications 

 

Cycle  Sequence Settings 

 

Softener System Setup (programming)  

 

Bypass Valve Description & Diagrams 

 

Installation 

 

Installer Settings 

 

Hardness, Override, Regen Time & Time of Day 

 

Normal  Operating & Error Displays,  Power Loss 

 

Low Salt Warning & Resetting It 

 

Start Up  Instructions 

 

Replacement Parts & Valve Repair 

 

Front Cover, Drive Assembly and Piston 

 

Injector Assembly & Refill Port Assembly 

 

Drain Line 3/4" Assembly & Flow Controls 

 

Drain Line 1" Assembly & Flow Controls 

 

Water Meter & Bypass Valve 

 

Installation Fitting Assemblies & Service Wrench 

 

Control Valve Servicing 

 

Troubleshooting  Procedures 

 

 

PREINSTALLATION INSTRUCTIONS 

 

This unit has a control valve which enables the setting of not only the length of each regeneration cycle but 

also the  order in which cycles  (steps of regeneration) occur. The following pages instruct how to set  the 

treatment  unit’s  sequence  of  cycles,  cycle  times,  salt  dose,  exchange  capacity,  and  gallon 

capacity/regeneration time. A salt warning option may also be included. 

 

THE  DEALER... 

1. Read this page, 

GENERAL INSTRUCTIONS, INSTALLER SETTINGS, NORMAL, OPERATING 

DISPLAYS,

 and 

LOW SALT WARNING. 

2. Complete the 

CYCLE SEQUENCE SETTINGS.

 

3. Complete the 

SOFTENER SYSTEM SETUP.

  

a. Cycle Times 

b. Choose Softener or Filter 

c. Set Salt Dose 

d. Set Capacity 

e. Set How Gallon Capacity Will be Calculated 

f. Set Regeneration Time Option 

g. Select or Turn Off Low Salt Warning 

 

THE INSTALLER..

1. Read Bypass Valve page. 

2. Read 

GENERAL INSTRUCTIONS, NORMAL OPERATING DISPLAYS, 

and

 RESETTING LOW 

SALT WARNING

 (if applicable). 

3. Be sure 

CYCLE SEQUENCE SETTINGS

 and 

SOFTENER SYSTEM SETUP 

are done before leaving for 

installation. 

4. Follow 

INSTALLATION INSTRUCTIONS, INSTALLER SETTINGS, TIME OF DAY,

 and 

RESETTING 

SALT AMOUNT

 (if applicable). 

5. Follow 

START UP INSTRUCTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание T../MA-BTB series

Страница 1: ...E PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN INTERRUPTION OF SERVICE OR APPARENT PRODUCT MALFUNCTION AN...

Страница 2: ...which cycles steps of regeneration occur The following pages instruct how to set the treatment unit s sequence of cycles cycle times salt dose exchange capacity and gallon capacity regeneration time...

Страница 3: ...gh them When moving through any displays or programmings if no buttons are pressed within five minutes the display returns to normal operating displays Any changes made prior to the five minute time o...

Страница 4: ...5CS Press UP or DOWN until FILL appears Press NEXT to go to Step 6CS Press REGEN to return to previous step Step 6CS Press UP or DOWN until END appears Press NEXT to exit Cycle Sequence Press REGEN t...

Страница 5: ...ss as calcium carbonate for the system based on the pounds of salt that will be used Calculate the pounds of salt using the fill time previously selected Grains capacity is affected by the fill time T...

Страница 6: ...f no water usage when the volume capacity reaches 0 zero See Setting Options Table for more detail Press NEXT to go to Step 10S Press REGEN to return to previous step Step 10S Press NEXT until SALT LE...

Страница 7: ...on water to the unit while also providing untreated water to the distribution system See Figure 1 2 Bypass Position The inlet and outlet handles point to the center of the bypass The system is isolate...

Страница 8: ...sure relief valve Also be certain that local codes are not violated 4 Do not locate unit where it or its connections including the drain and overflow lines will ever be subjected to room temperatures...

Страница 9: ...allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back siphoned into the conditioner INSTALLER SETTINGS Step 1I Press NEXT and UP simultaneously fo...

Страница 10: ...l the error or alert is reset by the user Press NEXT to exit Installer Display Setting Press REGEN to return to the previous step SET TIME OF DAY Time of day should only need to be set if the battery...

Страница 11: ...maining for that step to be completed The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed MANUAL REGENERATION Someti...

Страница 12: ...ACKWASH and the remaining time is counting down Unplug transformer to prevent valve from moving to the next cycle 3 Open the inlet handle of the bypass valve very slightly allowing water to fill the t...

Страница 13: ...12 REPLACEMENT PARTS...

Страница 14: ...13 REPLACEMENT PARTS...

Страница 15: ...14 REPLACEMENT PARTS...

Страница 16: ...15 REPLACEMENT PARTS...

Страница 17: ...16 REPLACEMENT PARTS...

Страница 18: ...17 INSTALLATION FITTING ASSEMBLIES...

Страница 19: ...orce on top of the drive bracket while deflecting the bracket slightly to the left by pressing on the side of the upper right corner Pressing to the left helps the drive gears mesh with the drive cap...

Страница 20: ...t may be used on black o rings but is not necessary Avoid any type of lubricants including silicone on red or clear lip seals Reinsert the drive cap assembly and piston into the spacer stack assembly...

Страница 21: ...ing dilute sodium bisulfite or vinegar Do not use a wire brush If necessary replace the flow control flow control retainer o ring or the elbow o ring Reseat the flow control so the rounded end with le...

Страница 22: ...tating the assembly as you pull it out will enable it to be removed more easily There are three o rings one under the rotor cap one on the rotor stem and one on the rotor seal Replace worn o rings Cle...

Страница 23: ...assy d Piston not in home position d Press NEXT and REGEN or momentarily unplug PC board power e Motor gears not fully engaged Motor wires broken Failed motor e Check motor and wiring f Center drive g...

Страница 24: ...23 Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204 783 1599 fax www waterite com...