background image

7

8. 

8. 

Connect esd grounding cord (electrostatic discharge)  
only black models

Connect esd grounding cord (electrostatic discharge) 
only black models

COnnECTinG | EsD (2/3)

Содержание FHD TREND

Страница 1: ...peration 9 9 setup menu 12 10 measurement application TMA 16 version 1 1 6 2017 11 01 11 system update 19 12 license activation 21 13 Technical specifications 22 14 system requirements 25 15 maintenance 26 16 warranty 26 17 license agreement 26 18 ergonomic recommendations 26 19 DECLARATION OF CONFORMITY 27 manual TAGARNO FHD TREND ...

Страница 2: ...ARNO 14 Always turn off the system before unplugging when possible WARNINGS Read all safety information before you use the product Please pay attention when you see the warning label on the product The product is a digital magnifying system consisting of a camera unit PCBs mechanical parts and a power supply The product is intended for marketing worldwide and is designed for manual visual inspecti...

Страница 3: ...ual HDMI DVI Cable Hexagon Tool Base XY table Power Supply Camera Arm USB Memory Stick USB 3 0 A B Cable Rod Washers Screws XPLUS FHD control box XKEY Control box 5 yOU HAVE RECEIVED OPTIONS HDMI HDMI cable ...

Страница 4: ...d horizontally on top of the base Fasten the two washers with the screw on top of the rod Pull the button and place the camera arm on the rod The complete microscope with base 6 ASSEMBLING assembling base 1 2 How to install video tagarno com video tutorials how to install tagarno trend mp4 ...

Страница 5: ...ng xy TABLE 2 2 Assemble XY table block and rod with three screws Fasten the two washers with the screw on top of the rod Pull the button and place the camera arm on the rod The complete microscope with XY Table ...

Страница 6: ...canner USB 2 0 Host Output 5V 500mA 6 USB 3 0 output USB 3 0 Type B Socket Computer USB 3 0 Device Self powered 7 Ethernet RJ 45 Ethernet wall socket Ethernet LAN 100BASE TX 1000BASE T 8 ESD Snap Socket 10mm ESD Grounding point ESD Grounding point Only black models CONNECTING BASE XY table 1 3 Connect USB cable control box monitor Ethernet and power supply in that order 7 CONNECTING Connect keyboa...

Страница 7: ...7 8 8 Connect ESD grounding cord electrostatic discharge Only black models Connect ESD grounding cord electrostatic discharge Only black models CONNECTING ESD 2 3 ...

Страница 8: ...ors HDMI DVI cable Live image The microscope can be connected directly to a monitor Live image Live image HDMI DVI cable Live image image capture Live image and image capturing through USB3 0 3rd part software See system recommended third party under system requirements You are still able to connect monitor s as described above USB3 0 CONNECTING COMBINATIONS 3 3 ...

Страница 9: ...g to the lens you are using Adjust the friction tension to set your personal preference Power on off 8 Operation 1 Use the pin to rotate the camera inside the camera head 2 Tilt the camera head vertically to each side How to use video tagarno com video tutorials how to use tagarno trend mp4 ...

Страница 10: ...ns Auto Snapshot on off when activated via the Setup menu When taking a picture an information window will appear for a few seconds showing the file name and storage location The image will be saved on the inserted USB memory stick If a USB memory stick is not attached the image is saved internally on the microscope provided the share file mode is turned on Otherwise an error message will appear a...

Страница 11: ... on the control box to zoom in Push this button on the control box to zoom out The magnification level will show via On Screen Display Manual Focus Turn autofocus off by pushing both zoom buttons plus and minus on the control box at the same time You can now adjust focus manually with the help of the zoom buttons Push this button on the control box to adjust focus if you wish to focus on something...

Страница 12: ... needs to be carried out on a flat surface Take 3 zoom levels into consideration to perform as precise measurements as possible The magnification settings prior to performance will be restored 3 Closeup Lens Indicate which lens is mounted on your TAGARNO microscope to get the right magnification levels displayed in the On Screen Display when zooming in and out 4 Start magnification Choose the star...

Страница 13: ...shown in the OSD 7 System units Choose to display metrics or imperial units when using the microscope 8 Numeric format Here you can select the numeric format based on your preference Choose between 1 234 56 1 234 56 or 1 234 56 9 System language The following languages are available as system language Danish English French German Hungarian Italian Romanian Russian and Spanish 10 Keyboard layout Se...

Страница 14: ...ring units When the Ruler is chosen the system will automatically start in manual focus set to focus on the part of the object farthest away It is also possible to save an image with graphics from the Ruler function 4 Watermark Create an info field on captured images with an image prefix time stamp horizontal field of view microscope model plus serial number and or import and add a custom defined ...

Страница 15: ... between the lines and mark the tolerance Insert a grid with a user defined number of lines and state the wanted distance between the lines Save as template 4 inFo 1 System information This enables you to see model number serial number firmware versions and other information about the product 2 Storage information When choosing this function an information window will appear showing the internal s...

Страница 16: ...bration will fail If the Result says FAIL try choosing to Live ON to adjust the position of the calibration sheet and recalibrate by pressing Run calibration again 6 Click OK to save the new calibration and close calibration state 7 Click Cancel to close without saving the calibration new Calibration lineary This is a calibration method where you use a reference line and state the line length The ...

Страница 17: ...g a Calibration The application will store and recall a calibration so that you do not have to recalibrate every time the software has been closed When you readjust a calibration the camera focus locks This means that you maybe have to readjust the physical distance between the camera and the object you are looking at focus height to display the image sharply When recalling a calibration it is imp...

Страница 18: ...mouse Text Annotation This function makes it possible to add text annotations anywhere in the window Use the Keyboard to type the text Move the text box to the wanted location and left click the mouse to confirm the position Arrow Annotation With this tool it is possible to add arrow annotations anywhere in the window Use the left mouse button to place the endpoints The second point is the end of ...

Страница 19: ...formatted 3 If the file s is in a ZIP folder unzip the files and make sure that only the correct installation file s and no ZIP folders or previous system update files appear on the memory stick Note File names always have the following format tagarno_fhd_system_vx_xx image tagarno_fhd_system_vx_xx system tagarno_fhd_system_vx_xx update x_xx denoting the system version The installation file s is i...

Страница 20: ... procedure as described above entering system update STEP 5 vErIFy INSTALLATION 1 Verify the system update by checking that the Application version displayed in the Setup menu Info System information matches the version of the system update file STEP 6 AccESS THE APPLIcATION A new menu point will appear in the Setup menu under pt 3 Applications showing the new application Note To activate the appl...

Страница 21: ...ed the product After installation of a TAGARNO application you might need to activate a unique license key file to be able to access and use the application To activate a license key on your TAGARNO microscope follow the steps below Note The license can only be paired with the microscope which has the serial number stated in your license The license can not be removed and transfered to another mic...

Страница 22: ... 25 30 50 60Hz Camera zoom 30x optical Autofocus Yes Power consumption 16 8W Standby consumption 0 7W Storage 5 60ºC 23 140ºF 20 90 RH Operation 5 40ºC 41 104ºF 20 80 RH Work height Min 100mm 3 9 Max 310mm 12 2 Work depth 385mm 15 2 Auto Monitor Detect Yes Plug connection HDMI output USB 3 0 output USB 2 0 input Ethernet and Sub D for Control box 13 Technical specifications h w d ...

Страница 23: ...25 30 50 60Hz Camera zoom 30x optical Autofocus Yes Power consumption 16 8W Standby consumption 0 7W Storage 5 60ºC 23 140ºF 20 90 RH Operation 5 40ºC 41 104ºF 20 80 RH Work height Min 50mm 1 9 Max 320mm 12 6 Work depth 385mm 15 2 Monitor Auto Detect Yes Plug connection HDMI output USB 3 0 output USB 2 0 input Ethernet and Sub D for Control box h w d ...

Страница 24: ...or Set time Watermark Optional Close up lens Activate file share mode Set date Verification lines Optional Lenses Dimensions Lens to object distance Magnification on 22 screen 3 58 mm 2 3 333 mm 13 1 1 2x 35 4x 4 included 58 mm 2 3 250 mm 9 8 1 6x 47 3x 5 58 mm 2 3 200 mm 7 9 1 9x 59 3x 10 58 mm 2 3 100mm 3 9 3 8x 115 5x 25 58 mm 2 3 34mm 1 34 9 6x 297 1x Recommended monitor format Panel format 16...

Страница 25: ...AM Monitor resolution 1920x1080 FULL HD 1080p 25 30Hz OS Desktop Laptop Windows 7 8 or 10 with DirectX 11 Memory 4GB CPU Intel Core Dual 3 0GHz or i3 2 4GHz 3rd generation named 3xxx Intel Core i3 3 2GHz 3rd generation named 3xxx Hard Disc Space 1GB required SSD type recommended Connections USB 3 0 xHCI host controller Intel chipset recommended Integrated Graphics Intel HD Graphics Dedicated graph...

Страница 26: ...very and will be free from defects in material and workmanship for a period of 24 months 2 years from date of invoice from Supplier This warranty covers a The replacement of defective parts b All labour costs to exchange defective parts in product c Complete functions test of product before return to end user s site d Return transport costs of product from TAGARNO to end user s site The warranty o...

Страница 27: ...e consisting of a camera unit and a 12V power supply is in compliance with the following European directive EMC DIRECTIVE 2014 30 EU By conforming to the following harmonised standards EN 61010 1 2010 EN 61326 1 2013 The declaration is issued by MANUFACTURER TAGARNO A S TAGARNO A S Sandøvej 4 8700 Horsens Denmark 45 76251111 mail tagarno com www tagarno com TAGARNO FHD TREND Type no 850000 19 DECL...