background image

11

Additional Information

Break-In

Your TAGA Harmony amplifier sounds great immediately after it is taken out of the 

carton but as all vacuum tube amplifiers, this amplifier requires a “break-in” period to 

reach its full sonic capabilities. 

During the “break-in” period it is recommended to operate the amplifier at moderate 

volume levels.

The first level of the “break-in” is reached after approximately 10 hours of play.  

The optimal level of the “break-in” is reached after approximately 40 to 60 hours of play.  

It is recommended to avoid one-time short periods of operation unless the amplifier 

reaches the first “break-in” level. When the amplifier is turned on, it should operate for 

around 4-6 hours.

Turn off procedure

Make sure to turn off the amplifier first when powering down your system.

Note!

 If the amplifier was turned off even for a short period of time, you should wait 

at least 2 minutes before turning it back on. Do not turn it ON then OFF and then ON 

again in quick succession. 

Follow this procedure each time you turn your amplifier OFF / ON. This precaution will 

minimize the stress (high voltages) on internal components.

Tube Cage

For your safety and to protect the vacuum tubes this amplifier is equipped with the 

vacuum tube cage which is factory installed.

It is not recommended to remove the cage unless it is required to change the vacuum 

tubes.

When the cage is removed - do not touch the vacuum tubes - they may be hot and 

burn the skin!  

To remove the cage:

1.  Turn off the amplifier.

2.  Unplug the Power Cable from the electrical outlet.

3.  Wait for approximately 30 minutes to cool down vacuum tubes.

4.  Remove the cage by pulling it in upward.

Make sure to reinstall the cage for the regular operation.

Vacuum Tube Replacement

The lifetime of vacuum tubes may vary and depends on their operation time and 

ambient temperature, playback volume levels and the number of on and off cycles.

Note! 

The warranty time for vacuum tubes is shorter than for other components of this 

device - for more details check your warranty terms or contact a local dealer.

Replacement vacuum tubes are not supplied with this product.

To replace the vacuum tube:

1.  Remove the tube cage – check “Tube Cage” for more details.

2.  Make sure that the vacuum tubes are cool.

Содержание TTA-1000

Страница 1: ...TTA 1000 HIGH END VACUUM TUBE INTEGRATED AMPLIFIER Instruction Manual ...

Страница 2: ...d is natural and fresh with deep multidimensional soundstage The audiophile grade ALPS volume potentiometer ensures minimal noises and channels crosstalk and has excellent operational feel and limits errors between the two channels The high end class gold plated speaker terminals and gold plated ceramic tube sockets offer almost lossless audio signal transmission to speakers Analog inputs with hig...

Страница 3: ...s Safety Instructions 4 Important Safety Instructions 5 Remote controller 6 Front and Rear Panel 7 Hooking up speaker cables 8 Hooking up the amplifier 9 Operation 10 Additional Information 11 Specifications 13 ...

Страница 4: ...SERT CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE THE FUSE ONLY WITH THE SAME AMPERAGE AND VOLTAGE TYPE REFER REPLACEMENT TO QUALIFIED SERVICE PERSONNEL WARNING UNIT MAY BECOME HOT ALWAYS PROVIDE ADEQUATE VENTILATION TO ALLOW FOR COOLING DO NOT PLACE NEAR A HEAT SOURCE OR IN SPACES THAT CAN RESTRICT VENTILATION An exclamation mark in a triangle is intended to alert the user to the...

Страница 5: ...onvenience receptacles and the point where they exit from the product 12 Lightning For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable systems This will prevent damage to the product due to lightning and power line surges 13 Overloading Do not overload wal...

Страница 6: ...es Do not mix new batteries with old batteries or different kinds of batteries If the batteries run out remove the old batteries and replace them with new ones within several minutes If the batteries are placed incorrectly they can cause explosion Remove the batteries if the remote control is not used for a long period of time Do not handle and store the batteries together with metallic tools Use ...

Страница 7: ...n 6 Volume Buttons w s Remote Controller Front Panel 1 Input Selector 2 Remote Controller Sensor 3 CD LINE Phono MM Phono MC Inputs Led Indicators 4 Power Switch ON and OFF 5 Volume Regulator with Power Volume Change Led Indicator Front and Rear Panel SR SR CD LINE MM MC POWER PHONO INPUT VOLUME MIN MAX TTA 1000 STEREO AMPLIFIER ON OFF ...

Страница 8: ...cm 5 feet of extra cable at the amplifier end to facilitate positioning and installation of the amplifier Do not use staples nails or other metal objects to secure the cables You will get the best sound quality and least amount of hum by keeping the cables away from other electrical wires and cables Pay attention to connecting the polarity of the amplifier correctly with the speakers in each speak...

Страница 9: ...onnect cable not supplied with this product connect the turntable to the PHONO input Screw in a ground cable of the turntable to the Phono Ground Screw 6 Preamplifier Output PRE OUT this amplifier is equipped with the preamplifier output Using an RCA interconnect cable not supplied with this product you can connect to it external equipment power amplifier powered speakers active subwoofer etc The ...

Страница 10: ...e type of phono cartridge your turntable is equipped with choose the MM or MC input 4 Turn on your audio source and start playback 5 Regulate volume on the amplifier to adjust the level of sound Note Check Additional Information for other useful operating instructions Note High volume levels can damage this amplifier and or speakers This may void your warranty Volume Regulator front panel and remo...

Страница 11: ...ou turn your amplifier OFF ON This precaution will minimize the stress high voltages on internal components Tube Cage For your safety and to protect the vacuum tubes this amplifier is equipped with the vacuum tube cage which is factory installed It is not recommended to remove the cage unless it is required to change the vacuum tubes When the cage is removed do not touch the vacuum tubes they may ...

Страница 12: ...ich is a direct equivalent of the factory installed one Gently but firmly place the new vacuum tube in the socket 6 If you change the output power vacuum tubes KT88 make sure to bias your amplifier check Vacuum Tube Biasing for more details 7 Make sure to reinstall the cage for the regular operation Vacuum Tube Biasing KT88 Only the output power tubes KT88 need to be biased manually This procedure...

Страница 13: ...Phono MM MC Outputs RCA Pre Out Line inputs Sensitivity 450mV Impedance RCA 50K ohm Phono input MM MC Input impedance 47Kohms 47ohms Gain 40dB 60dB Output voltage 400mV 400mV THD 1 AC Power Power Consumption 230 240V 50Hz 400W Dimensions H x W x D 22 5 x 45 x 37 5 cm Weight net 24 kg pc We reserve the right to change the technical data and the design of the product without notice as a result of fu...

Страница 14: ...14 Notes ...

Страница 15: ...15 Notes ...

Страница 16: ...do not dispose of this product as household waste or commercial waste Waste electrical and electronic equipement should be appropriately collected and recycled as required by practices established for your country For information on recycling of this product please contact your local authorities your household waste disposal service or the shop where you purchased the product Your product is marke...

Отзывы: