F3 series 100X5R service manual
16
6.2.4
Frequency
Distortion
Measure signal level on distortion
response
analyser
analyser.
output: 1kHz, 1
V rms
Set as 0 dB reference
measurement
mode:signal
20Hz 0.0dB ±0.02
level.
20kHz -0.16dB
±0.05
6.2.5
Measure
Distortion
distortion
analyser
output: 20Hz -
20kHz, 1 V
rms
measurement
mode: THD
wide
bandwidth
Leave
AUDIO OUTPUT
connected
to distortion analyser input.
Measure THD on distortion
analyser.
20Hz < 0.003
1kHz < 0.003
20kHz <0.06
6.2.6
Check mute
Distortion
Measure signal level on distortion
operation
analyser
analyser.
channel
output: 1 kHz,
1 V rms
Set as 0 dB reference.
measurement
mode: signal
Mute amplifier
level.
Signal level should reduce by more
than 80 dB.
6.2.7
6.2.8
Reassemble
unit
6.2.9
Clean with
damp cloth