F3 series 100X5R service manual
12
5.1fault finding flow chart:
5.2 Test equipment required
Equipment
Specification
Digital Multimeter
Accuracy better than 0.5% in V and mV ranges
Oscilloscope
Bandwidth >100 MHZ
Various Leads
With faulty modules the uC control can be bypassed by disconnecting the 6-way ribbon from the Module Under
Test (MUT). With this disconnected the uC will no allow mains to the module as it believes it to be not fitted.
Also the output relay will not close as it requires a pull down to ground to operate. Therefore both the ribbon
cable and the respective connector need linking out:
Ribbon: Link pins 2 & 6
Header: Link pins 2 & 4
N.B. Be aware, the protection is now not operational, and prolonged abuse of the module will result in
damage.
5.3 Functional test procedure
No
Action
Test Equipment
Details
4.2.1
Disconnect all
cables from
amplifier
4.2.2
Check voltage
Read ratings label on rear of
setting
amplifier
4.2.3
Check fuse type
Open fuse holder in power socket on
rear panel.
Rated supply Fuse Type
230 V AC
T1AL 250V
115V AC
T1A 125V
100V AC T1A 125V
4.2.4
Check fuse
Multimeter set
Fuse and spare fuse should be low
resistance
to O
resistance
4.2.5
Remove unit
See Section 3.0
cover
4.2.5
Check fuses F1-
Multimeter set
Fuses are on the MicroController PCB
F7
to O
Содержание 100 5R Series
Страница 1: ...amplifier 100x5R service manual ...
Страница 10: ...F3 series 100X5R service manual 6 ...
Страница 25: ...F3 series 100X5R service manual 21 Sheet 2 of 3 283 MICROCONTROLLER PCB SCH28206 02 03 ...
Страница 26: ...F3 series 100X5R service manual 22 Sheet 3 of 3 283 MICROCONTROLLER PCB SCH28206 03 03 ...
Страница 27: ...F3 series 100X5R service manual 23 ...
Страница 29: ...F3 series 100X5R service manual 25 Sheet 2 of 2 283 AMPLIFIER SCHEMATIC SCH28301 02 04 ...
Страница 30: ...F3 series 100X5R service manual 26 9 5 100X5R TAG BUS PCB ...