5. Printer Configuration
The printer incorporates a number of configurable option, each of which has a number of setting.
5.1. To change the setting of any option, follow the procedure below:
1) Ensure the printer is OFF
2) Press and hold the Mode Button: 5 seconds. The Status light will flash 5 times to show that the
printer is in configuration mode. Release the Mode button
3) Press the Mode button the same number of time as the option that you wish to change
4) After a short delay, the Status Light will flash the same number of times as the option that you
have chosen. If you have made a mistake at this stage, simply wait: after a delay, the printer will
power-on without changing any options.
5) To proceed with configuration, press the Mode button the same number of time as the setting that
you wish to make
6) After a short delay, the Status light will flash the same number of times as the setting that you
have made
7) After a further delay, the printer will power ON with the new setting
Option Description
Setting
n°
Setting
1
RS232 Protocole
Request specific to TAG Heuer Timing
2
RS232 Baud Rate
1
115200
2
57600
4
19200
5
9600
7
2400
Other
Under request at TAG Heuer Timing
3
Flow Control
Under request at TAG Heuer Timing
4
Font
1
Arial 16 (24 characters / line)
2
Arial 12 (32 characters / line)
3
Arial 9 (42 characters / line)
4
Arial 8 (48 characters / line)
5
Character Format
1
Normal
2
Double Width
3
Double Height
4
Double Width and Height
6
Print Denstity
1
Lowest
4
Highest
7
Printer Currint
1
Highest
4
Lowest
8
Print Format
1
Standard paper, normal printing
2
Standard paper, upside down printing
3
Labels, Normal printing
4
Labels, upside down printing
9
Sleep/Wake up
1
Never sleeps
2
Off after 1 minutes
3
Off after 2 minutes
4
Off after 5 minutes
5
Off after 10 minutes