The indicated value is MPa.
1MPa = 10.2kgf/cm
2
The pressure adjusted from the regulator is
displayed.
At the time of dispensing, the needle moves
at the same time as the operation sound of
the solenoid valve.
: Vacuum adjust
Increase negative pressure : CCW
Decrease negative pressure : CW
If the dispensing material has a low
viscosity, the material will be natural fall.
Set the negative pressure inside barrel for
natural fall prevention.
: Air out port
It is the outlet of the set air pressure.
Connect to a foot switch or external
device.
It is a connector for the discharge input
signal and the discharge end signal ,
⚠ If power is applied to the terminals, it
will break down.
: Exhaust
Pressure release in Barrel and Vacuum
generator outlet. Keep it clean so that there
are no foreign objects. After the discharge
is completed, it may cause poor
decompression and drop in pressure ,
: Air in
Air supply to the controller.
Install the outer diameter Ø6 air tube.
Foot Switch
Tighten after inserting it into the control
connector. Click to give a discharge signal
to the controller .
Power cord
Be sure to perform earth processing..