THE-100 Series 

 

Rev 1 

2020/11/27 

11/18 

Copyright © 2020 by TAEHA CORP. All Rights Reserved 

4

 

Name and function of each part 

Image 

Names and displays 

Function 

 

    : ER Switch 

I : Power ON 

0 : Power OFF 

  : Holder 

Small 0.5 +A Fuse(include spare 1 EA) 

: Acceptable 

Power cord inlet. 

(Be sure to process earth.) 

 

  : Display 

Time mode : Increases by the set value. 

Steady mode : Increases as signal on. 

  : Time Up 

Press  for  2  seconds  or  more  to  increase 

rapidly. 

  : Time Down 

Press for 2 seconds or more to make a rapid 

descent. 

: Shot switch 

Time mode : Press once to turn on only the 

set value. 

Steady mode : Continue ON while pressing 

: Time/Steady select s/w 

Time  mode  :    Press  once  to  turn  on  only 

the set value. 

Steady mode : Continue ON while pressing 

 

 

Rotate 

Description 

Raise 

pressure 

CW 

Slowly rotate to 

the set pressure 

De- 

compress 

CCW 

After setting the 

pressure lower 

than the set 

pressure, raise 

the pressure 

When pressure is set : Unlock state 

When the pressure setting is 

completed : Set to the lock state. 

Adjust the dispensing pressure. 

The adjusted dispensing pressure is 

displayed on the pressure gauge.. 

UNLOCK 

LOCK 

Содержание THE-100 Series

Страница 1: ...THE 100 Series User manual...

Страница 2: ...3 Features of THE 100 series 9 3 1 THE 100 series 9 3 2 Appearance and specification 10 4 Name and function of each part 11 5 How to use 13 5 1 Ready 13 5 2 Negative pressure adjustment 14 5 3 Needle...

Страница 3: ...ur products When using this product please read this manual carefully pay enough attention to safety and handle it properly The safety precautions have been classified into Danger and Caution Danger m...

Страница 4: ...loor is wet or if there is too much moisture It may cause electric shock 5 Be careful not to damage the cable place heavy objects on it or fold it In case it is damaged it may cause electric shock Pre...

Страница 5: ...ensation wind and rain etc 2 Exposure to direct sunlight for a long time will degrade accuracy of the equipment Do not install store or use in areas where there is direct sunlight 3 When installing in...

Страница 6: ...aution 1 When cleaning or repairing the equipment be sure to turn off the power and check the internal power supply for complete discharging and then have it carried out by a qualified maintenance spe...

Страница 7: ...ent and the following cases the warranty period will be one year in the event of defects Following 1 In case you modify the equipment without permission by Taeha Corp 2 If someone other than the techn...

Страница 8: ...ax 86 512 6805 2921 2 4 Precautions Danger 1 Be sure to use the designated power supply The basic power of the equipment is designated as AC220V 50 60Hz 2 Be sure to use the designated air pressure Th...

Страница 9: ...THE 100 Series_automatic fluid dispenser is a precision instrument that uses an advanced microprocessor and air pulse speed up circuit to make full use of the liquid discharge rate quickly and stably...

Страница 10: ...air pressure Max 990kPa oil free Dry air Pneumatic adjustment range 0 02 0 6 MPa Shot time adjustment range 0 03 9 99 sec Operation Time operation Fixed quantity dispensing Steady operation Continuous...

Страница 11: ...ess for 2 seconds or more to make a rapid descent Shot switch Time mode Press once to turn on only the set value Steady mode Continue ON while pressing Time Steady select s w Time mode Press once to t...

Страница 12: ...tural fall prevention Air out port It is the outlet of the set air pressure Connect to a foot switch or external device It is a connector for the discharge input signal and the discharge end signal If...

Страница 13: ...1 4 Turn on the Combination switch When turned on the lamp lights up 2 Insert the joint of the adapter assembly into the Air out port on the front of the controller 3 Before adding material clean the...

Страница 14: ...re to prevent free fall Caution If the negative pressure is too large air bubbles will be generated inside the barrel and the material after discharge can be sucked so set the negative pressure approp...

Страница 15: ...ial scattering if the Needle is thick and high pressure 2 Factors that can change the discharge rate Dispensing time Small amount Needle change Middle amount Pressure Large amount 1 Operate in Steady...

Страница 16: ...Timing chart Image Description Terminal number 1 2 Shot input signal Terminal number 3 4 Shot signal end Relay contact Caution Please note that applying power to the terminals may cause a malfunction...

Страница 17: ...end signal is maintained up to the shot input signal STEADY Shot input signal holding time Min 3msec SHOT TIME occurrence delay time Max 5msec Shot end signal time 30msec INTERVAL Shot input signal ho...

Страница 18: ...aged material replace it with a new product 2 Do not use the product if the barrel is scratched or damaged Barrel is disposable Replace it after it has been used for metered dispensing 3 Adapter assem...

Отзывы: