background image

PCP-005/015/050/150/500/1000 

 

Rev 1.1 

2021/02/03 

5/45 

Copyright © 2021 by TAEHA CORP. All Rights Reserved

 

2

 

Pro Pump System (PCP) Feature   

2.1

 

Pro Pump System   

 

This system is a precise pump made using a special eccentric screw structure, it has organizational 

benefits that are simple in construction but excellent in performance. 

It is also a high-performance dispenser equipped with dedicated software that comprises a control 

panel to perform a variety of tasks. 

It  is  a  good  system  that  is  designed  to  provide  convenience,  accuracy,  and  diversity  for  applying 

dispensers. 

 

Please read this manual to get the most out of your product and do what you want. 

 

 

2.2

 

Pro Pump System Feature 

 

 

Precise and Consistent volume of fluid is dispensed even when environmental factors 

affect viscosity and pressure in the container.

 

 

 

Clean dispensing is provided without ball-up through the suck back function, which 

sucks back the fluid drop formed at the nozzle tip.(Nozzle rotation is not restricted.) 

 

 

Consistent dispensing is possible without fluid surging because the pro-pump provides 

consistent flow by maintaing a stable pressure. 

 

 

Disassembly and reassembly for maintenance and cleaning is easy because of simple 

structure of the pumping unit. 

 

 

Precise volume of fluid with filler is dispensed without impairing fillers under the cavity 

displacement dispensing process. 

 

 

Содержание PCP-005 Series

Страница 1: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 1 45 Copyright 2021 by TAEHA CORP All Rights Reserved PRO PUMP SYSTEM PCP 005 015 050 150 500 1000 Series Operation Manual...

Страница 2: ...re Specification 6 2 4 Pro Pump Controller Feature Specification 8 2 5 PCP Standard System 9 2 6 PCPM Module Type System 10 3 Name of each part 11 4 Pro Pump Operation 12 4 1 Precautions on Use and As...

Страница 3: ...150 500 1000 Rev 1 1 2021 02 03 3 45 Copyright 2021 by TAEHA CORP All Rights Reserved 6 6 PCP 1000 Partlist 41 7 Maintenance 42 7 1 Alarm Display and Action 43 7 2 Inspection and Measures 44 7 3 Trou...

Страница 4: ...separate agreement and the following cases the warranty period will be one year in the event of defects Following 1 In case you modify the equipment without permission by Taeha Corp 2 If someone other...

Страница 5: ...read this manual to get the most out of your product and do what you want 2 2 Pro Pump System Feature Precise and Consistent volume of fluid is dispensed even when environmental factors affect viscosi...

Страница 6: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 6 45 Copyright 2021 by TAEHA CORP All Rights Reserved 2 3 Pro Pump Feature Specification Figure 1 Pro Pump Feature...

Страница 7: ...D mm 230 x 27 x 27 280 x 29 x 29 312 x 29 x 29 Weight 400g 650g 700g Input Pressure 0 0 6 MPa Max Dosing Pressure 3 0MPa 2 0MPa 1 0MPa 1 2MPa Viscosity cPs 1 1 000 000 Dosing Volume Rev 0 0049ml 0 01...

Страница 8: ...nel Button Rotary Knob Operation Mode Time Steady Metering 3 Mode Operation Memory 16ch User Define Operating Air Pressure 5kgf cm Humidity less than 5 Air Filter 5 Pressure Regulator 0 7kgf cm Air In...

Страница 9: ...tridge tank etc are separated from the Pro Pump Figure 3 Pro Pump System Table 3 Pro Pump System No Description Model Q ty Remarks 1 1K Pump Pro Pump 1 Set 2 Pro Pump Controller Procon 100 1 Set Pro P...

Страница 10: ...is integral with the Pro Pump unit Figure 4 Pro Pump Module Type PCPM System Table 4 PCPM System No Description Model Q ty Remarks 1 1K Pump Pro Pump 1 Set 2 Pro Pump Controller Procon 100 1 Set Pro P...

Страница 11: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 11 45 Copyright 2021 by TAEHA CORP All Rights Reserved 3 Name of each part Figure 5 Name of each part...

Страница 12: ...d Stator Connection Do not activate the Pump without applying the material to the stator If so even for a short duration of time there might be a damage on the stator 2 Eliminating bubbles before liqu...

Страница 13: ...on the Pro Pump controller Procon 100 3 Make sure the pressure supplied to the material supplier barrel cartridge tank etc is adequate Table 5 Suitable seting for each material Less than 2000cPs 1 2k...

Страница 14: ...ght 2021 by TAEHA CORP All Rights Reserved 5 Pro Pump Disassemble 5 1 PCP 005 015 050 Disassemble This section describes the procedure for disassembling the Pro Pump PCP 005 015 050 for its maintenanc...

Страница 15: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 15 45 Copyright 2021 by TAEHA CORP All Rights Reserved 2 Use a spanner to remove the union cap Figure 10...

Страница 16: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 16 45 Copyright 2021 by TAEHA CORP All Rights Reserved 3 Remove the stator sleeve associated with luer lock adapter Figure 11...

Страница 17: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 17 45 Copyright 2021 by TAEHA CORP All Rights Reserved 4 Turn the two wrench bolts counterclockwise to release the motor Figure 12...

Страница 18: ...150 500 1000 Rev 1 1 2021 02 03 18 45 Copyright 2021 by TAEHA CORP All Rights Reserved 5 Secure one side with the repair tool Use a dedicated spanner to slowly rotate stator counterclockwise to relea...

Страница 19: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 19 45 Copyright 2021 by TAEHA CORP All Rights Reserved 6 Turn the 2 bolts counterclockwise to release the chamber Figure 14...

Страница 20: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 20 45 Copyright 2021 by TAEHA CORP All Rights Reserved 7 Remove rotor and seal block by rocking them to the left and right Figure 15...

Страница 21: ...2 03 21 45 Copyright 2021 by TAEHA CORP All Rights Reserved 5 2 PCP 150 500 Disassemble This section describes the procedure for disassembling the Pro Pump PCP 150 500 for its maintenance 1 Prepare th...

Страница 22: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 22 45 Copyright 2021 by TAEHA CORP All Rights Reserved 2 Use a spanner to remove orifice adapter Figure 17...

Страница 23: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 23 45 Copyright 2021 by TAEHA CORP All Rights Reserved 3 Hold the pump and remove the union cap using a spanner Figure 18...

Страница 24: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 24 45 Copyright 2021 by TAEHA CORP All Rights Reserved 4 Turn the two wrench bolts counterclockwise to release the motor Figure 19...

Страница 25: ...150 500 1000 Rev 1 1 2021 02 03 25 45 Copyright 2021 by TAEHA CORP All Rights Reserved 5 Secure one side with the repair tool Use a dedicated spanner to slowly rotate stator counterclockwise to relea...

Страница 26: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 26 45 Copyright 2021 by TAEHA CORP All Rights Reserved 6 Turn the two wrench bolts counterclockwise to release the chamber Figure 21...

Страница 27: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 27 45 Copyright 2021 by TAEHA CORP All Rights Reserved 7 Remove motor and seal block by rocking them to the left and right Figure 22...

Страница 28: ...21 02 03 28 45 Copyright 2021 by TAEHA CORP All Rights Reserved 5 3 PCP 1000 Disassemble This section describes the procedure for disassembling the Pro Pump PCP 1000 for its maintenanace 1 Prepare the...

Страница 29: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 29 45 Copyright 2021 by TAEHA CORP All Rights Reserved 2 Turn the two wrench bolts counterclockwse to release the inlet adapter Figure 24...

Страница 30: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 30 45 Copyright 2021 by TAEHA CORP All Rights Reserved 3 Turn the two wrench bolts counterclockwise to release the motor Figure 25...

Страница 31: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 31 45 Copyright 2021 by TAEHA CORP All Rights Reserved 4 Hold a pump and remove the luer lock adapter using a spanner Figure 26...

Страница 32: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 32 45 Copyright 2021 by TAEHA CORP All Rights Reserved 5 Hold a pump and remove the union cap using a spanner Figure 27...

Страница 33: ...150 500 1000 Rev 1 1 2021 02 03 33 45 Copyright 2021 by TAEHA CORP All Rights Reserved 6 Secure one side whit the repair tool Use a dedicated spanner to slowly rotate stator counterclockwise to relea...

Страница 34: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 34 45 Copyright 2021 by TAEHA CORP All Rights Reserved 7 Turn the two wrench bolts counterclockwise to release the chamber Figure 29...

Страница 35: ...PCP 005 015 050 150 500 1000 Rev 1 1 2021 02 03 35 45 Copyright 2021 by TAEHA CORP All Rights Reserved 8 Remove motor and seal block by rocking them to the left and right Figure 30...

Страница 36: ...P 005 C Bolt M3x55 2 High strength 3 PCP 005 3 Stator Sleeve 1 SUS303 D PCP 005 D O Ring SS8 1 FKM 1472 4 PCP 005 4 Stator 1 SUS303 E PCP 005 E O Ring SS5 1 FKM 1472 5 PCP 005 5 Chamber 1 AL2024 F PCP...

Страница 37: ...lt M3x55 2 High strength 3 PCP 015 3 Stator Sleeve 1 SUS303 D PCP 015 D O Ring SS8 1 FKM 1472 4 PCP 015 4 Stator 1 SUS303 E PCP 015 E O Ring SS5 1 FKM 1472 5 PCP 015 5 Chamber 1 AL2024 F PCP 015 F O R...

Страница 38: ...lt M3x55 2 High strength 3 PCP 050 3 Stator Sleeve 1 SUS303 D PCP 050 D O Ring SS8 1 FKM 1472 4 PCP 050 4 Stator 1 SUS303 E PCP 050 E O Ring SS5 1 FKM 1472 5 PCP 050 5 Chamber 1 AL2024 F PCP 050 F O R...

Страница 39: ...olt M3x55 2 High strength 2 PCP 150 2 Union cap 1 SUS303 E PCP 150 E O Ring SS8 1 FKM 1472 3 PCP 150 3 Stator 1 SUS303 F PCP 150 F O Ring SS5 1 FKM 1472 4 PCP 150 4 Chamber 1 AL2024 G PCP 150 G O Ring...

Страница 40: ...olt M3x55 2 High strength 2 PCP 500 2 Union cap 1 SUS303 E PCP 500 E O Ring SS8 1 FKM 1472 3 PCP 500 3 Stator 1 SUS303 F PCP 500 F O Ring SS5 1 FKM 1472 4 PCP 500 4 Chamber 1 AL2024 G PCP 500 G O Ring...

Страница 41: ...2 PCP 1000 2 Union cap 1 SUS303 E PCP 1000 E Bolt M3x55 2 High strength 3 PCP 1000 3 Stator 1 SUS303 F PCP 1000 F O Ring SS8 1 FKM 1472 4 PCP 1000 4 Chamber 1 AL2024 G PCP 1000 G O Ring SS5 1 FKM 1472...

Страница 42: ...alfunctions caused by various factors please perform occasional user determined and periodic within a year inspections Danger Be sure to take necessary measures such as manual mode of the equipment em...

Страница 43: ...ication of abnormal phenomena is as follows Alarms that may occur due to hardware protection or internal element breakage Alarms that may occur from incorrect settings when setting motion programs and...

Страница 44: ...eriodically Keep it clean to prevent so that the contamination by dust or solution does not interfere with the operation of the equipment Supplied Air Occasionally Check the piping connection joints o...

Страница 45: ...k if there is a change in the tank air supply pressure 6 Check if there is a leak in the liquid connection fitting If there is a leak in nozzle end during the standby time after dispensing 1 Check if...